Download Print this page

IBM Flex System p24L Installation And Service Manual page 180

Compute node
Hide thumbs Also See for Flex System p24L:

Advertisement

BA050001 • BA06000C
BA050001
Explanation: Failed to reboot a partition in logical partition mode
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA050004
Explanation: Failed to locate service processor device tree node.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA05000A
Explanation: Failed to send a boot failed message
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060008
Explanation: No configurable adapters found by the Remote IPL menu in the SMS utilities
Response: This error occurs when the firmware cannot locate any LAN adapters that are supported by the remote
IPL function. Verify that the devices in the remote IPL device list are correct using the SMS menus.
BA06000B
Explanation: The system was not able to find an operating system on the devices in the boot list.
Response: Go to Boot problem resolution.
BA06000C
Explanation: A pointer to the operating system was found in non-volatile storage.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware