B7006951 • B7006970
B7006951
Explanation: An error occurred because a partition needed more NVRAM than was available.
Response: Use the management console to delete one or more partitions.
B7006952
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006953
Explanation: PHYP NVRAM is unavailable after a service processor reset and reload.
Response: Go to Isolating firmware problems.
B7006954
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006955
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006956
Explanation: An NVRAM failure was detected.
Response: Go to Isolating firmware problems.
B7006965
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006970
Explanation: PCI host bridge failure
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2.
If the problem persists, use the PCI expansion card (PIOCARD) problem isolation procedure to determine the
failing component.
144
Power Systems: IBM Flex System p24L Compute Node Installation and Service Guide