Download Print this page

IBM Flex System p24L Installation And Service Manual page 183

Compute node
Hide thumbs Also See for Flex System p24L:

Advertisement

BA060201
Explanation: Failed to read the VPD "boot path" field value
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060202
Explanation: Failed to update the VPD with the new "boot path" field value
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060300
Explanation: An I/O error on the adapter from which the boot was attempted prevented the operating system from
being booted.
Response:
1. Using the SMS menus, select another adapter from which to boot the operating system, and reboot the system.
2. Attempt to reboot the system.
3. Go to Boot problem resolution.
BA07XXXX
Explanation: self configuring SCSI device (SCSD) controller failure
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA090001
Explanation: SCSD DASD: test unit ready failed; hardware error
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060201 • BA090001
Chapter 8. Troubleshooting
171

Advertisement

loading
Need help?

Need help?

Do you have a question about the Flex System p24L and is the answer not in the manual?

Questions and answers