652-770 • 652-88X
652-770
Explanation: A non-critical error has been detected: intermediate system bus address parity error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2C8
v FFC_292
652-771
Explanation: A non-critical error has been detected: intermediate or system bus data parity error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2C8
v FFC_292
652-772
Explanation: A non-critical error has been detected: intermediate or system bus time-out error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2D2
v FFC_292
652-773
Explanation: A non-critical error has been detected: intermediate or system bus data parity error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_227
652-88X
Explanation: The CEC or SPCN reported a non-critical error.
1. Schedule deferred maintenance.
2. Refer to the entry MAP in this system unit system service guide, with the 8-digit error and location codes, for the
necessary repair action.
3. If the 8-digit error and location codes were NOT reported, then run diagnostics in problem determination mode
and record and report the 8-digit error and location codes for this SRN.
Response:
278
Power Systems: IBM Flex System p24L Compute Node Installation and Service Guide