Explanation: Informational system log entry only.
Response: No corrective action is required.
B7000302
Explanation: System firmware failure
Response:
1. Collect the platform dump information.
2. Go to Isolating firmware problems.
B7000441
Explanation: Service processor failure. The platform encountered an error early in the startup or termination
process.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7000443
Explanation: Service processor failure.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7000601
Explanation: Informational system log entry only.
Response: No corrective action is required.
Note: This code and associated data can be used to determine why the time of day for a partition was lost.
B7000602
Explanation: System firmware detected an error condition.
Response:
1. Collect the event log information.
2. Go to Isolating firmware problems.