BA040030
Explanation: The firmware was not able to build the UID properly for this system. As a result, problems may occur
with the licensing of the AIX operating system.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA040035
Explanation: The firmware was unable to find the plant of manufacture in the VPD. This may cause problems with
the licensing of the AIX operating system.
Response: Verify that the machine type, model, and serial number are correct for this server. If this is a new server,
check for server firmware updates; install the updates if available.
BA040040
Explanation: Setting the machine type, model, and serial number failed.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA040050
Explanation: The h-call to switch off the boot watchdog timer failed.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA040060
Explanation: Setting the firmware boot side for the next boot failed.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA040030 • BA040060
Chapter 8. Troubleshooting
167
Need help?
Do you have a question about the Flex System p24L and is the answer not in the manual?
Questions and answers