1100262D • 11002632
1100262D
Explanation: 3.3V reg_pgood fault.
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2. Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
1100262E
Explanation: 2.5V reg_pgood fault.
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2. Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
1100262F
Explanation: 1.0V power fault in the server.
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2. Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
11002630
Explanation: VRM CP0 core pGood fault.
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2. Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
11002632
Explanation: VRM CP0 cache pGood fault.
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2. Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
94
Power Systems: IBM Flex System p24L Compute Node Installation and Service Guide
Need help?
Do you have a question about the Flex System p24L and is the answer not in the manual?
Questions and answers