Explanation: Reallocation failed due to disk out of alternate sectors. Replace the FRU identified by diagnostics.
Response:
Failing Item:
v FFC_722
2D14-3002
Explanation: Addressed device failed to respond to selection. Replace the FRU identified by diagnostics.
Response:
Failing Item:
v FFC_722
2D14-3010
Explanation: Disk returned wrong response to adapter. Replace the FRU identified by diagnostics.
Response:
Failing Item:
v FFC_722
2D14-3020
Explanation: Storage subsystem configuration error. Use MAP3150 to determine resolution.
Response:
2D14-3100
Explanation: Controller detected device bus interface error. Use MAP3150 to determine resolution.
Response:
2D14-3109
Explanation: Controller timed out a device command. Use MAP3150 to determine resolution.
Response:
2D14-3110
Explanation: Device bus interface error. Use MAP3150 to determine resolution.
Response: