IBM Flex System p24L Installation And Service Manual page 350

Compute node
Hide thumbs Also See for Flex System p24L:

Advertisement

2770-103 • 2770-601
2770-103
Explanation: Loop back test failure. Replace the IBM Flex System EN4132 2-port 10Gb RoCE Adapter
Response:
Failing Item:
v FFC_2770
2770-201
Explanation: Loop back test failure. Do the following steps one at a time, in order, and rerun the test after each step:
1. Reseat the cable.
2. Replace the cable.
3. Verify that the network is functional.
4. Verify that the network switch is functional.
Response:
Failing Item:
v CABLE
v NETWORK
2770-301
Explanation: Loop back test failure. Do the following steps one at a time, in order, and rerun the test after each step:
1. Reseat the cable.
2. Replace the cable.
3. Verify that the network is functional.
4. Verify that the network switch is functional.
5. Go to Performing the checkout procedure.
Response:
Failing Item:
v CABLE
v NETWORK
v FFC_2770
2770-601
Explanation: Error Log Analysis indicates adapter hardware error Replace the IBM Flex System EN4132 2-port 10Gb
RoCE Adapter
Response:
Failing Item:
v FFC_2770
338
Power Systems: IBM Flex System p24L Compute Node Installation and Service Guide