B700BA01 • B700F105
B700BA01
Explanation: During analysis of a previous serviceable error, a request to activate a FRU fault indicator was not
successful.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B700BAD1
Explanation: The platform firmware detected an error.
Response: Go to Isolating firmware problems.
B700BAD2
Explanation: System firmware detected an error.
Response:
1. Collect the event log information.
2. Go to Isolating firmware problems.
B700F103
Explanation: System firmware failure
Response:
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to Isolating firmware problems.
B700F104
Explanation: Operating system error. System firmware terminated a partition.
Response: Check the Management Module event log for partition firmware error codes (especially BA00F104); then,
take the appropriate actions for those error codes.
B700F105
Explanation: System firmware detected an internal error
Response:
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to Isolating firmware problems.