B2005123 • B2005149
B2005123
Explanation: Informational system log entry only.
Response: No corrective action is required.
B2005127
Explanation: Timeout occurred during a main store dump IPL.
Response: There was not enough memory available for the dump to complete before the timeout occurred. Retry
the main store dump IPL, or else power on the partition normally.
B2005135
Explanation: A problem occurred during the startup of a partition. There was an error writing the partition main
storage dump to the partition load source. The main store dump startup will continue.
Response: Look for other errors and resolve them.
B2005137
Explanation: A problem occurred during the startup of a partition. There was an error writing the partition main
storage dump to the partition load source. The main store dump startup will continue.
Response: Look for other errors and resolve them.
B2005145
Explanation: A problem occurred during the startup of a partition. There was an error writing the partition main
storage dump to the partition load source. The main store dump startup will continue.
Response: Look for other errors and resolve them.
B2005148
Explanation: A problem occurred during the startup of a partition. An error occurred while doing a main storage
dump that would have caused another main storage dump. The startup will not continue.
Response: Go to Isolating firmware problems.
B2005149
Explanation: A problem occurred during the startup of a partition while doing a Firmware Assisted Dump that
would have caused another Firmware Assisted Dump.
Response: Check for server firmware updates; then, install the updates if available.
122
Power Systems: IBM Flex System p24L Compute Node Installation and Service Guide
Need help?
Do you have a question about the Flex System p24L and is the answer not in the manual?
Questions and answers