IBM Flex System p24L Installation And Service Manual page 415

Compute node
Hide thumbs Also See for Flex System p24L:

Advertisement

SSSS-108
Explanation: The bus test failed.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v FFC_SSSS
SSSS-110
Explanation: The media format is corrupted.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v FFC_SSSS
SSSS-112
Explanation: The diagnostic test failed.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v FFC_SSSS
SSSS-114
Explanation: An unrecoverable hardware error.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Response:
Failing Item:
v FFC_SSSS
SSSS-108 • SSSS-114
Chapter 8. Troubleshooting
403