SmartRelay 3 system
Locking in the non-authorised time period (open relay contacts)
always
Controller: Opens
relay contacts
(locked) as soon as
authorisation ends
in the time zone
plan. Identification
media close relay
contacts (unlock)
during non-author-
ised time period for
pre-set pulse dura-
tion.
10.11.2 Extended configuration with SmartOutput modules
Unlocking in the authorised period (close relay contacts)
Automatic unlocking
always
only if locked
Not possible
(Manual)
only if locked
Controller: Opens
relay contacts
(locked) as soon as
authorisation ends
in the time zone
plan. Identification
media close relay
contacts (unlock)
during non-author-
ised time period for
pre-set pulse dura-
tion.
Controller: Closes relay
contacts (unlocked) as
soon as authorisation
begins in the time zone
plan. Not affected by
identification media
during the authorised
period.
SmartOutput module:
Closes relay contacts
(unlocked) as soon as
authorisation begins in
the time zone plan. Not
affected by identification
media during the
authorised period.
always
Controller: Opens
relay contacts
(locked) as soon as
identification me-
dium is activated.
Identification media
close relay contacts
(unlock) during
non-authorised
time period for pre-
set pulse duration.
Manual unlocking
always
Not possible
10. SREL3 ADV in LSM
only if locked
Not possible
only if locked
Controller: Closes relay
contacts (unlocked) as
soon as identification
medium is actuated
after the start of the
authorisation in the
period. Thereafter, no
influence by
identification media in
the remaining authorised
period.
SmartOutput module:
Closes relay contacts
(unlocked) as soon as
authorisation begins in
the time zone plan and
identification medium is
reserved. No affected by
identification media
during the remaining
authorised period.
136 / 189