Selftest Failures - HP Vizualize,Visualize b2000 Supplementary Manual

Unix workstation
Hide thumbs Also See for Vizualize,Visualize b2000:
Table of Contents

Advertisement

Selftest Failures

Chassis codes are the key to debugging selftest errors. If a failure is found during selftest,
chassis codes are displayed in the LCD. The procedure for using these codes to debug a
failure is as follows:
1. Using Table 3-2, which starts on the next page, find the chassis code listed on the LCD.
2. To get additional information about failures from the Boot Console Handler, use the
Service Menu's pim, pdt, and ChassisCodes commands.
In the following table, the FRU column shows messages printed on the LCD that refer to
system FRUs. Only FLT codes have FRUs associated with them. Some WRN codes are also
device specific, especially to IODC calls; for example, 8xxx codes. TST and INI codes do not
necessarily correspond to any FRU. All codes are listed in numeric order.
NOTE
Because the B2000 workstation is a single-board system, references to the
I/O BD (I/O board) in chassis codes displayed on the LCD and listed in Table
3-2 are actually references to the SYS BD (system board).
Chapter 3
Troubleshooting
Selftest Failures
53