Selftest Failures; Memory Failures - HP Visualize J5000 - Workstation Service Handbook

J class workstation
Hide thumbs Also See for Visualize J5000 - Workstation:
Table of Contents

Advertisement

Selftest Failures

Chassis codes are the key to debugging selftest errors. If a failure is found during
selftest, chassis codes are displayed in the LCD. The procedure for using these codes
to debug a failure is as follows:
6. Using Table 4–1, find the chassis code listed on the LCD.
Codes 7000 through 7Dxx are memory errors.
Codes CBxx through 500F in Table 4–1 are HPMC errors.
7. A 7Fxx code means a memory SIMM error. Figure 4–3 is a layout of the
memory SIMMs on the CPU board that goes down to the SIMM pair. To contin-
ue beyond the pair, run Offline Diagnostics.
To get additional information about failures from the boot console interface, use the
Service menu pim, pdt, and ChassisCode commands.
In the following table, the FRU column shows messages printed on the LCD that refer
to system FRUs. Only FLT codes have FRUs associated with them. Some WARN codes
are also device-specific, especially to IODC calls; for example, 8XXY codes. Test and
INIT codes don't correspond to any FRU. All codes are listed in numeric order.
For the FRUs labled 'Selftest CPU 0', there is also a corresponding CPU x code, where x
indicates the CPU number.

Memory Failures

The J Class system requires special Memory Page Deallocation (PDC) to be
implemented. This PDC feature allows the workstation to provide information to the
operating system about memory failures.
HP-UX 10.x uses PDC information to map out failing memory areas and continue
normal operation. You can use the command memrpt with the detail switch to obtain
information about the Memory Page Deallocation Table (PDT) as well as single bit
errors logged by the system.
# /usr/sbin/sysdiag
Enter
DUI >logtool
LOGTOOL> memrpt detail
The PDT can also be checked using the pdt command in the Service menu of the
boot console handler (Refer to Chapter 9). If a failing SIMM is replaced, use the
command pdt clear in the Service menu to clear out the PDT.
HP-UX 9.0x will halt upon detecting the presence of bad memory at boot up and
display the following message:
ISL booting hpux
Secondary Loader 9000/700
Revision 3.08
Booting /hp-ux
2103692 + 319488 + 309344 start 0x25030
panic: Memory self-test failed
Enter
Enter
Troubleshooting
4–9