Troubleshooting
Fan Faults and Warnings
Fan Faults and Warnings
This section provides the fault (FLT) and warning (WRN) messages you will see in the LCD if
there is a problem with a fan in the B2000 workstation.
A chassis code which indicates that a fan has failed (FLT D01n) or is running too slowly
(WRN D02n) within a B2000 workstation specifies the fan number, n. Table 3-1 lists the fan
numbers and their names. To locate the correct fan, see Figure 3-5 on the next page.
Table 3-1. Fan Numbers and Corresponding Names
Fan Number (n)
Name of the Fan
2
I/O fan
4
System fan
5
Processor fan
Here is an example of a fault message for the system fan (4):
FLT D014 SYS BD
fan 4: failure!
Here is an example of a warning message for the processor fan (5):
WRN D025 SYS BD
fan 5: too slow!