HP Vizualize,Visualize b2000 Supplementary Manual page 76

Unix workstation
Hide thumbs Also See for Vizualize,Visualize b2000:
Table of Contents

Advertisement

Troubleshooting
Selftest Failures
Table 3-2. Chassis Codes for the B2000 Workstation
Ostat
Code
FRU
FLT
CBFF
SYS BD
INI
CC0n
SYS BD
INI
CC1n
SYS BD
INI
CC2n
SYS BD
INI
CC3n
SYS BD
INI
CC4n
SYS BD
TST
D000
SYS BD
WRN
D004
SYS BD
INI
D005
SYS BD
INI
D006
SYS BD
WRN
D007
SYS BD
FLT
D01n
SYS/IO
WRN
D02n
SYS/IO
76
Message
multiple HPMCs
CPU n OS rendezvs
CPU n early rend
CPU n rendezvous
CPU n cache rend
CPU n mem rendez
micro controller
micro not resp
set dom1 fan spd
set dom2 fan spd
bad microctl cmd
fan n : failure!
fan n : too slow!
Description
A High-Priority Machine Check occurred
while processing another HPMC.
Slave CPU n entering the final
rendezvous, waiting for the operating
system to awaken it.
Slave CPU n entering the early
rendezvous, waiting for the monarch CPU
to initialize scratch RAM and other
system state.
Slave CPU n entering rendezvous. Slave
CPUs enter this rendezvous numerous
times during boot.
Slave CPU n entering cached rendezvous,
waiting for the monarch CPU to configure
the system bus.
Slave CPU n entering memory
rendezvous, waiting for the monarch CPU
to select a boot device.
Firmware is initializing communications
with the system controller.
Firmware detected a communications
error with the system controller.
Firmware is initializing communications
with the system controller.
Firmware is initializing communications
with the system controller.
Firmware detected a communications
error with the system controller.
Firmware detected fan n stopped.
Firmware detected fan n is running too
slowly.
Chapter 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Visualize b2000C3700 - workstation

Table of Contents