Table 26. Dataitem Keywords for Chassis Location
dataitem
Used to get or set the fan
speed of all fans in the
chassis. Value is percent of
fanspeed
the maximum fan speed. See
Section 16, "Fan Control and
Monitoring" on page 132
more information.
This is used to get or set the
Location field in the chassis
FRU and is sent out as a part
location
of SNMP and UDP alarts. This
is only used with the chassis
location.
MPCMM0001 Chassis Management Module Software Technical Product Specification
Download from Www.Somanuals.com. All Manuals Search And Download.
Description
Get/Set
Both
for
Both
The Command Line Interface (CLI)
CLI Get Output
The percentage of the max speed,
"Emergency Shut Down", or "Local
Control". For example, 80 for 80% of
the max speed.
"Shelf Address: <address>"
Where:
<address> is a space-separated list
of two-digit, hex numbers if the
address' type/len byte is 0, decoded
string otherwise
Valid Set Values
A numerical value
between 0 and 100
(i.e., "70"),
"localcontrol", or
"emergencyshutdow
n"
(localcontrol is not
supported on the
MPCHC0001
chassis fan tray.)
Location String less
than 16 characters
in length.