Summary of Contents for Intel MFS5000SI - Multi-Flex Server Compute Module
Page 1
Intel® Compute Module MFS5000SI User Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D90834-005...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
See also Intel® Server Boards and Server Chassis Safety Information at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Intel® Server Boards and Server Chassis Safety Information unter http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Consignes de sécurité...
Reinstalling enclosure cover: To protect internal components and for proper cooling and airflow, the compute module should not be inserted into the chassis with the cover removed; operating it without the enclosure cover in place can damage system parts. Intel® Compute Module MFS5000SI User Guide...
Tools and Supplies Needed ......................7 Installation Guidelines ......................... 7 Removing and Installing an Intel® Compute Module MFS5000SI ......... 7 Removing a Compute Module from the Server System ............. 7 Installing a Compute Module into the Server System ..............8 Opening and Closing the Top Cover ..................
Page 6
In Asia-Pacific region ........................ 50 Japan ............................50 Latin America ..........................50 B Warranty ........................53 Limited Warranty for Intel® Chassis Subassembly Products ..........53 Extent of Limited Warranty ....................53 Warranty Limitations and Exclusions .................. 54 Limitations of Liability ....................... 54 How to Obtain Warranty Service ....................
Page 7
Selección de la ubicación ......................79 Manipulación del equipo ......................79 Advertencias el acceso al sistema .................... 81 Descarga electrostática (ESD) ....................82 E Installation/Assembly Safety Instructions ............89 English ..........................89 Deutsch ..........................91 Français ..........................94 Español ..........................96 Italiano ..........................98 Intel® Compute Module MFS5000SI User Guide...
Page 8
Intel® Compute Module MFS5000SI User Guide...
Page 9
List of Tables Table 1. Compute Module Features................... 2 Table 2. Diagnostic LED Information..................46 Table 3. POST Error Beep Codes.................... 47 Intel® Compute Module MFS5000SI User Guide...
Page 10
Intel® Compute Module MFS5000SI User Guide...
Page 11
List of Figures Figure 1. Intel® Compute Module MFS5000SI ................. 1 Figure 2. Server Board ....................... 1 Figure 3. Component and Connector Locations................. 3 Figure 4. Configuration Jumper Locations ................. 4 Figure 5. Front Panel Connectors and Indicators............... 5 Figure 6. Removing Top Cover ....................9 Figure 7.
Page 12
Intel® Compute Module MFS5000SI User Guide...
Compute Module Features This chapter briefly describes the main features of the Intel® Compute Module MFS5000SI, as well as provides illustrations showing the location of important components and connections on the compute module. The Intel® Compute Module MFS5000SI is shown in the following pictures.
Page 14
Table 1. Compute Module Features Feature Description ® ® Processors Support for up to two Dual-Core Intel Xeon processors 5000 sequence Memory Support for up to 32 GB of fully-buffered DDR2 667-MHz DIMMs (FB-DIMM) Eight DIMM slots Support for DIMM sparing and memory mirroring Chipset Intel®...
These pins should have a jumper in place for normal system Clear operation. (Default) If these pins are jumpered, the CMOS settings will be cleared immediately. These pins should not be jumpered for normal operation. Intel® Compute Module MFS5000SI User Guide...
To avoid integration difficulties and possible board damage, your system must meet the requirements outlined below. Processor The Intel® Compute Module MFS5000SI supports up to two Multi-Core Intel® Xeon® Processors 5xxx Series. Memory A minimum of two fully-buffered DDR2 667 MHz DIMM(s) (FB-DIMM) should be installed.
Three power supplies will support 4 to 6 compute modules (in any slot) plus all other modules in the system. Any additional power supplies above minimum required (based on configuration) provides redundancy. Intel® Compute Module MFS5000SI User Guide...
4. Green on a component indicates that the component may be hot-swapped. See the instructions included with the hot-swap component for a complete list of installation or removal steps. Removing and Installing an Intel® Compute Module MFS5000SI Removing a Compute Module from the Server System 1.
2. If the compute module is installed in a server system, see “Removing a Compute Module from the Server System” on page 7 for removal instructions. 3. Carefully lay the compute module down on a flat, non-conductive surface, with the cover side up. Intel® Compute Module MFS5000SI User Guide...
(see letter “B”). Lift the top cover up and off the compute module. Caution: Always replace the top cover before installing the compute module into a server system. I/ O AF002402 Figure 6. Removing Top Cover Intel® Compute Module MFS5000SI User Guide...
Slide the top cover forward to the closed position until the retention latch fully engages. I/ O AF002403 Figure 7. Installing Top Cover Intel® Compute Module MFS5000SI User Guide...
Installing or Replacing a Processor Caution: Only processors validated for use in the Intel® Compute Module MFS5000SI should be installed. You may damage the compute module if an inappropriate processor is installed. Installing a Processor 1. Observe the safety and ESD information at the beginning of this manual and in the appendices.
Open the load plate (see letter “B”). Note: Do not touch the socket pins; they are very sensitive and easily damaged. TP02075 Figure 10. Opening Load Plate Intel® Compute Module MFS5000SI User Guide...
The underside of the processor has components that may damage the socket pins if installed improperly. Processor must align correctly with socket opening before installation. DO NOT DROP processor into socket. AF002223 Figure 12. Orienting and Installing Processor Intel® Compute Module MFS5000SI User Guide...
11. Ensure that the thermal material is intact on the bottom of the heatsink. 12. Align the heatsink over the processor, thermal material side down, with the captive screws in line with the holes on the heatsink retention module. Press down firmly on the heatsink. Intel® Compute Module MFS5000SI User Guide...
13. Press firmly on the captive screws and tighten them, alternating between screws in a diagonal manner (see tightening order in the following figure). Do not over-tighten the screws by using excessive force. TP02328 Figure 15. Installing Heatsink Intel® Compute Module MFS5000SI User Guide...
Remove the second processor air baffle by rocking the air baffle back and forth until it breaks off (see letter “A” in the following figure). AF002410 Figure 16. Removing Second Processor Air Baffle Intel® Compute Module MFS5000SI User Guide...
16. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 17. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page 4. Remove the processor air duct. I/ O AF002404 Figure 18. Removing Processor Air Duct Intel® Compute Module MFS5000SI User Guide...
AF002221 Figure 19. Removing the Heatsink 6. Push the lever handle down and away from the socket to release it. Fully raise the socket handle. TP02074 Figure 20. Lifting Processor Socket Handle Intel® Compute Module MFS5000SI User Guide...
Open the load plate (see letter “B”). TP02075 Figure 21. Opening Load Plate 8. Remove processor. Note: Do not touch the socket pins; they are very sensitive and easily damaged. AF002225 Figure 22. Removing Processor Intel® Compute Module MFS5000SI User Guide...
11. Lower the processor load plate (see letter “A” in the following figure). With your finger, push down on the load plate (see letter “B”). Lower the socket lever until it is fully latched (see letter “C”). AF002224 Figure 25. Lowering Load Plate and Socket Lever Intel® Compute Module MFS5000SI User Guide...
14. Press firmly on the captive screws and tighten them, alternating between screws in a diagonal manner (see tightening order in the following figure). Do not over-tighten the screws by using excessive force. TP02328 Figure 26. Re-installing Heatsink Intel® Compute Module MFS5000SI User Guide...
16. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 17. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
DIMMs are used for mirroring. Memory mirroring and memory sparing are mutually exclusive. Only one can be active at a time. See the Intel® Compute Module MFS5000SI Technical Product Specification for additional information regarding the memory sub-system. Intel® Compute Module MFS5000SI User Guide...
2. If the compute module is installed in a server system, see “Removing a Compute Module from the Server System” on page 7 for removal instructions. 3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page Intel® Compute Module MFS5000SI User Guide...
4. Remove the processor air duct. I/ O AF002404 Figure 29. Removing Processor Air Duct 5. Locate the DIMM sockets. 6. Holding the DIMM by the edges, remove it from it’s packaging. Intel® Compute Module MFS5000SI User Guide...
“C”) until the DIMM is fully seated and the retaining clips (see letter “D”) are locked firmly into place. Important: Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot. AF002453 Figure 30. Installing DIMMs Intel® Compute Module MFS5000SI User Guide...
9. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 10. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page 4. Remove the processor air duct. I/ O AF002404 Figure 32. Removing Processor Air Duct Intel® Compute Module MFS5000SI User Guide...
(see letter “A” in the following figure). This will slightly lift the DIMM from its socket. Holding the DIMM by the edges, remove it from the socket (see letter “B”). Important: Store the removed DIMM in an anti-static package. AF002454 Figure 33. Removing DIMMs Intel® Compute Module MFS5000SI User Guide...
7. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 8. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
5. Locate the mezzanine card socket on the server board. 6. With a Phillips* screwdriver, remove four screws from the server board. I/ O I/ O AF002456 Figure 35. Removing Screws from Server Board Intel® Compute Module MFS5000SI User Guide...
7. With a 1/4-inch nut driver, install the four standoffs that shipped with the mezzanine card. I/ O AF002457 Figure 36. Installing Standoffs for Mezzanine Card Intel® Compute Module MFS5000SI User Guide...
Carefully press the mezzanine card into place until it is fully seated in the socket and resting on the standoff supports. I/ O AF002407 Figure 37. Installing Mezzanine Card Intel® Compute Module MFS5000SI User Guide...
2. If the compute module is installed in a server system, see “Removing a Compute Module from the Server System” on page 7 for removal instructions. 3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page Intel® Compute Module MFS5000SI User Guide...
4. Locate the mezzanine card. With a Phillips* screwdriver, remove the four screws securing the mezzanine card to the standoffs. I/ O I/ O AF002458 Figure 39. Removing Screws from Mezzanine Card Intel® Compute Module MFS5000SI User Guide...
5. Holding the mezzanine card by its edges, gently lift it from the socket and store it in an anti-static package. I/ O AF002406 Figure 40. Removing Mezzanine Card Intel® Compute Module MFS5000SI User Guide...
8. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 9. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
2. If the compute module is installed in a server system, see “Removing a Compute Module from the Server System” on page 7 for removal instructions. 3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page Intel® Compute Module MFS5000SI User Guide...
10. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page 8 11. Run Setup to restore the configuration settings to the RTC. Intel® Compute Module MFS5000SI User Guide...
Is the operating system properly loaded? Refer to the operating system documentation. • Are all device drivers properly installed? • Are all installed components and the installed operating system listed in the Intel® Compute Module MFS5000SI Tested Hardware and Operating System List? Intel® Compute Module MFS5000SI User Guide...
Characters on the screen appear distorted or incorrect • No available storage • Network problems Try the solutions in the order given. If you cannot correct the problem, contact your service representative or authorized dealer for additional help. Intel® Compute Module MFS5000SI User Guide...
Characters are Distorted or Incorrect Check the following: • Is the video monitor properly adjusted? See the manufacturer’s documentation for operating instructions. • Are the video signal cable and power cable connected properly? Intel® Compute Module MFS5000SI User Guide...
No Available Storage Check the following: • Verify in the Intel® Modular Server Control GUI that virtual drive(s) are assigned to the compute module. • Ensure drive(s) assigned to the compute module are installed and operating properly.
Devices are Not Recognized within the Operating System Operating systems include a limited set of device drivers by default. Ensure that you install all necessary drivers at the time you install the operating system. Intel® Compute Module MFS5000SI User Guide...
Diagnostic LED Information The Intel® Compute Module MFS5000SI includes a number of diagnostic LEDs on the front of the compute module that can aid in troubleshooting your system. The following table lists these LEDs along with a usage description of each LED.
Page 59
The following table contains a partial list of the POST error beep codes enabled for the Intel® Compute Module MFS5000SI. The beep code sounds only when a critical error occurs or when the BIOS fails to boot to the operating system. Please note that not all error conditions are supported by BIOS beep codes.
Page 60
Intel® Compute Module MFS5000SI User Guide...
Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). For an updated support contact list, see http://www.intel.com/support/9089.htm/...
Chile Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 Intel® Compute Module MFS5000SI User Guide...
Page 63
Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Compute Module MFS5000SI User Guide...
Page 64
Intel® Compute Module MFS5000SI User Guide...
“as is” unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 68
Intel® Compute Module MFS5000SI User Guide...
Product Ecology Requirements Intel has a system in place to restrict the use of banned substances in accordance with worldwide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all supplier, and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance.
Item Requirement Description Y/N/D Product Ecology All materials, parts and subassemblies must not contain restricted materials as defined in Intel’s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers – http:// supplier.intel.com/ehs/environmental.htm Product Ecology Europe - European Directive 2002/95/EC -...
Product Regulatory Compliance and Safety Markings No markings required on the board itself as it is evaluated as part of the end system. Intel® Compute Module MFS5000SI User Guide...
Page 72
Intel® Compute Module MFS5000SI User Guide...
Indicates shock hazards that result in serious injury or death if safety instructions are not followed. Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intel® Compute Module MFS5000SI User Guide...
AC power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Compute Module MFS5000SI User Guide...
Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Compute Module MFS5000SI User Guide...
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a Intel® Compute Module MFS5000SI User Guide...
Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Compute Module MFS5000SI User Guide...
Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
• Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Compute Module MFS5000SI User Guide...
Page 80
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Compute Module MFS5000SI User Guide...
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Compute Module MFS5000SI User Guide...
Vorsicht: Beachten Sie zur Vermeidung von Strahlung und Verletzungen die folgenden Hinweise: • Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Compute Module MFS5000SI User Guide...
Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Compute Module MFS5000SI User Guide...
Page 86
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Page 87
Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Compute Module MFS5000SI User Guide...
à la terre, exempte de charge statique, composants orientés vers le haut. Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Compute Module MFS5000SI User Guide...
Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Compute Module MFS5000SI User Guide...
Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Compute Module MFS5000SI User Guide...
Page 92
CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Compute Module MFS5000SI User Guide...
Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Compute Module MFS5000SI User Guide...
Page 95
Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Compute Module MFS5000SI User Guide...
To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). Intel® Compute Module MFS5000SI User Guide...
Page 102
• Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Intel® Compute Module MFS5000SI User Guide...
Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Compute Module MFS5000SI User Guide...
Page 104
Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. Intel® Compute Module MFS5000SI User Guide...
Page 105
Telekommunikationsleitungen mit dem Modem bestehen; • "mit einer geerdeten Wechselstromsteckdose ausgerüstet sein; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Compute Module MFS5000SI User Guide...
Procédez comme suit: 1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Compute Module MFS5000SI User Guide...
Page 107
• "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Compute Module MFS5000SI User Guide...
Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Compute Module MFS5000SI User Guide...
Page 109
• "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Compute Module MFS5000SI User Guide...
1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Compute Module MFS5000SI User Guide...
Page 111
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Compute Module MFS5000SI User Guide...
Page 112
Intel® Compute Module MFS5000SI User Guide...
Need help?
Do you have a question about the MFS5000SI - Multi-Flex Server Compute Module and is the answer not in the manual?