Summary of Contents for Intel MFS5000SI - Multi-Flex Server Compute Module

  • Page 1 Intel® Compute Module MFS5000SI User Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D90834-005...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3: Safety Information

    See also Intel® Server Boards and Server Chassis Safety Information at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Intel® Server Boards and Server Chassis Safety Information unter http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Consignes de sécurité...
  • Page 4: Warnings

    Reinstalling enclosure cover: To protect internal components and for proper cooling and airflow, the compute module should not be inserted into the chassis with the cover removed; operating it without the enclosure cover in place can damage system parts. Intel® Compute Module MFS5000SI User Guide...
  • Page 5: Table Of Contents

    Tools and Supplies Needed ......................7 Installation Guidelines ......................... 7 Removing and Installing an Intel® Compute Module MFS5000SI ......... 7 Removing a Compute Module from the Server System ............. 7 Installing a Compute Module into the Server System ..............8 Opening and Closing the Top Cover ..................
  • Page 6 In Asia-Pacific region ........................ 50 Japan ............................50 Latin America ..........................50 B Warranty ........................53 Limited Warranty for Intel® Chassis Subassembly Products ..........53 Extent of Limited Warranty ....................53 Warranty Limitations and Exclusions .................. 54 Limitations of Liability ....................... 54 How to Obtain Warranty Service ....................
  • Page 7 Selección de la ubicación ......................79 Manipulación del equipo ......................79 Advertencias el acceso al sistema .................... 81 Descarga electrostática (ESD) ....................82 E Installation/Assembly Safety Instructions ............89 English ..........................89 Deutsch ..........................91 Français ..........................94 Español ..........................96 Italiano ..........................98 Intel® Compute Module MFS5000SI User Guide...
  • Page 8 Intel® Compute Module MFS5000SI User Guide...
  • Page 9 List of Tables Table 1. Compute Module Features................... 2 Table 2. Diagnostic LED Information..................46 Table 3. POST Error Beep Codes.................... 47 Intel® Compute Module MFS5000SI User Guide...
  • Page 10 Intel® Compute Module MFS5000SI User Guide...
  • Page 11 List of Figures Figure 1. Intel® Compute Module MFS5000SI ................. 1 Figure 2. Server Board ....................... 1 Figure 3. Component and Connector Locations................. 3 Figure 4. Configuration Jumper Locations ................. 4 Figure 5. Front Panel Connectors and Indicators............... 5 Figure 6. Removing Top Cover ....................9 Figure 7.
  • Page 12 Intel® Compute Module MFS5000SI User Guide...
  • Page 13: Compute Module Features

    Compute Module Features This chapter briefly describes the main features of the Intel® Compute Module MFS5000SI, as well as provides illustrations showing the location of important components and connections on the compute module. The Intel® Compute Module MFS5000SI is shown in the following pictures.
  • Page 14 Table 1. Compute Module Features Feature Description ® ® Processors Support for up to two Dual-Core Intel Xeon processors 5000 sequence Memory Support for up to 32 GB of fully-buffered DDR2 667-MHz DIMMs (FB-DIMM) Eight DIMM slots Support for DIMM sparing and memory mirroring Chipset Intel®...
  • Page 15: Connector And Component Locations

    Intel® 6321ESB I/O Controller Hub Power/Fault LEDs Intel® 5000P Memory Controller Hub (MCH) Power Switch Test Connector (manufacturing only) Activity and ID LEDs Serial Debug Connector (manufacturing only) Video Connector Figure 3. Component and Connector Locations Intel® Compute Module MFS5000SI User Guide...
  • Page 16: Configuration Jumpers

    These pins should have a jumper in place for normal system Clear operation. (Default) If these pins are jumpered, the CMOS settings will be cleared immediately. These pins should not be jumpered for normal operation. Intel® Compute Module MFS5000SI User Guide...
  • Page 17: Front Panel Connectors And Indicators

    To avoid integration difficulties and possible board damage, your system must meet the requirements outlined below. Processor The Intel® Compute Module MFS5000SI supports up to two Multi-Core Intel® Xeon® Processors 5xxx Series. Memory A minimum of two fully-buffered DDR2 667 MHz DIMM(s) (FB-DIMM) should be installed.
  • Page 18: Power Supply

    Three power supplies will support 4 to 6 compute modules (in any slot) plus all other modules in the system. Any additional power supplies above minimum required (based on configuration) provides redundancy. Intel® Compute Module MFS5000SI User Guide...
  • Page 19: Hardware Installations And Upgrades

    4. Green on a component indicates that the component may be hot-swapped. See the instructions included with the hot-swap component for a complete list of installation or removal steps. Removing and Installing an Intel® Compute Module MFS5000SI Removing a Compute Module from the Server System 1.
  • Page 20: Installing A Compute Module Into The Server System

    2. If the compute module is installed in a server system, see “Removing a Compute Module from the Server System” on page 7 for removal instructions. 3. Carefully lay the compute module down on a flat, non-conductive surface, with the cover side up. Intel® Compute Module MFS5000SI User Guide...
  • Page 21: Figure 6. Removing Top Cover

    (see letter “B”). Lift the top cover up and off the compute module. Caution: Always replace the top cover before installing the compute module into a server system. I/ O AF002402 Figure 6. Removing Top Cover Intel® Compute Module MFS5000SI User Guide...
  • Page 22: Replacing And Closing The Top Cover

    Slide the top cover forward to the closed position until the retention latch fully engages. I/ O AF002403 Figure 7. Installing Top Cover Intel® Compute Module MFS5000SI User Guide...
  • Page 23: Installing Or Replacing A Processor

    Installing or Replacing a Processor Caution: Only processors validated for use in the Intel® Compute Module MFS5000SI should be installed. You may damage the compute module if an inappropriate processor is installed. Installing a Processor 1. Observe the safety and ESD information at the beginning of this manual and in the appendices.
  • Page 24: Figure 9. Lifting Processor Socket Handle

    Open the load plate (see letter “B”). Note: Do not touch the socket pins; they are very sensitive and easily damaged. TP02075 Figure 10. Opening Load Plate Intel® Compute Module MFS5000SI User Guide...
  • Page 25: Figure 11. Removing Protective Shipping Cover

    The underside of the processor has components that may damage the socket pins if installed improperly. Processor must align correctly with socket opening before installation. DO NOT DROP processor into socket. AF002223 Figure 12. Orienting and Installing Processor Intel® Compute Module MFS5000SI User Guide...
  • Page 26: Figure 13. Removing Socket Protective Cover

    11. Ensure that the thermal material is intact on the bottom of the heatsink. 12. Align the heatsink over the processor, thermal material side down, with the captive screws in line with the holes on the heatsink retention module. Press down firmly on the heatsink. Intel® Compute Module MFS5000SI User Guide...
  • Page 27: Figure 15. Installing Heatsink

    13. Press firmly on the captive screws and tighten them, alternating between screws in a diagonal manner (see tightening order in the following figure). Do not over-tighten the screws by using excessive force. TP02328 Figure 15. Installing Heatsink Intel® Compute Module MFS5000SI User Guide...
  • Page 28: Figure 16. Removing Second Processor Air Baffle

    Remove the second processor air baffle by rocking the air baffle back and forth until it breaks off (see letter “A” in the following figure). AF002410 Figure 16. Removing Second Processor Air Baffle Intel® Compute Module MFS5000SI User Guide...
  • Page 29: Figure 17. Reinstalling Processor Air Duct

    16. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 17. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
  • Page 30: Replacing A Processor

    3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page 4. Remove the processor air duct. I/ O AF002404 Figure 18. Removing Processor Air Duct Intel® Compute Module MFS5000SI User Guide...
  • Page 31: Figure 19. Removing The Heatsink

    AF002221 Figure 19. Removing the Heatsink 6. Push the lever handle down and away from the socket to release it. Fully raise the socket handle. TP02074 Figure 20. Lifting Processor Socket Handle Intel® Compute Module MFS5000SI User Guide...
  • Page 32: Figure 21. Opening Load Plate

    Open the load plate (see letter “B”). TP02075 Figure 21. Opening Load Plate 8. Remove processor. Note: Do not touch the socket pins; they are very sensitive and easily damaged. AF002225 Figure 22. Removing Processor Intel® Compute Module MFS5000SI User Guide...
  • Page 33: Figure 23. Removing Protective Shipping Cover

    11. Lower the processor load plate (see letter “A” in the following figure). With your finger, push down on the load plate (see letter “B”). Lower the socket lever until it is fully latched (see letter “C”). AF002224 Figure 25. Lowering Load Plate and Socket Lever Intel® Compute Module MFS5000SI User Guide...
  • Page 34: Figure 26. Re-Installing Heatsink

    14. Press firmly on the captive screws and tighten them, alternating between screws in a diagonal manner (see tightening order in the following figure). Do not over-tighten the screws by using excessive force. TP02328 Figure 26. Re-installing Heatsink Intel® Compute Module MFS5000SI User Guide...
  • Page 35: Figure 27. Reinstalling Processor Air Duct

    16. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 17. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
  • Page 36: Installing And Removing Memory Modules

    DIMMs are used for mirroring. Memory mirroring and memory sparing are mutually exclusive. Only one can be active at a time. See the Intel® Compute Module MFS5000SI Technical Product Specification for additional information regarding the memory sub-system. Intel® Compute Module MFS5000SI User Guide...
  • Page 37: Installing Dimms

    2. If the compute module is installed in a server system, see “Removing a Compute Module from the Server System” on page 7 for removal instructions. 3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page Intel® Compute Module MFS5000SI User Guide...
  • Page 38: Figure 29. Removing Processor Air Duct

    4. Remove the processor air duct. I/ O AF002404 Figure 29. Removing Processor Air Duct 5. Locate the DIMM sockets. 6. Holding the DIMM by the edges, remove it from it’s packaging. Intel® Compute Module MFS5000SI User Guide...
  • Page 39: Figure 30. Installing Dimms

    “C”) until the DIMM is fully seated and the retaining clips (see letter “D”) are locked firmly into place. Important: Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot. AF002453 Figure 30. Installing DIMMs Intel® Compute Module MFS5000SI User Guide...
  • Page 40: Figure 31. Reinstalling Processor Air Duct

    9. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 10. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
  • Page 41: Removing Dimms

    3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page 4. Remove the processor air duct. I/ O AF002404 Figure 32. Removing Processor Air Duct Intel® Compute Module MFS5000SI User Guide...
  • Page 42: Figure 33. Removing Dimms

    (see letter “A” in the following figure). This will slightly lift the DIMM from its socket. Holding the DIMM by the edges, remove it from the socket (see letter “B”). Important: Store the removed DIMM in an anti-static package. AF002454 Figure 33. Removing DIMMs Intel® Compute Module MFS5000SI User Guide...
  • Page 43: Figure 34. Reinstalling Processor Air Duct

    7. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 8. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
  • Page 44: Installing And Removing Mezzanine Card

    5. Locate the mezzanine card socket on the server board. 6. With a Phillips* screwdriver, remove four screws from the server board. I/ O I/ O AF002456 Figure 35. Removing Screws from Server Board Intel® Compute Module MFS5000SI User Guide...
  • Page 45: Figure 36. Installing Standoffs For Mezzanine Card

    7. With a 1/4-inch nut driver, install the four standoffs that shipped with the mezzanine card. I/ O AF002457 Figure 36. Installing Standoffs for Mezzanine Card Intel® Compute Module MFS5000SI User Guide...
  • Page 46: Figure 37. Installing Mezzanine Card

    Carefully press the mezzanine card into place until it is fully seated in the socket and resting on the standoff supports. I/ O AF002407 Figure 37. Installing Mezzanine Card Intel® Compute Module MFS5000SI User Guide...
  • Page 47: Removing A Mezzanine Card

    2. If the compute module is installed in a server system, see “Removing a Compute Module from the Server System” on page 7 for removal instructions. 3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page Intel® Compute Module MFS5000SI User Guide...
  • Page 48: Figure 39. Removing Screws From Mezzanine Card

    4. Locate the mezzanine card. With a Phillips* screwdriver, remove the four screws securing the mezzanine card to the standoffs. I/ O I/ O AF002458 Figure 39. Removing Screws from Mezzanine Card Intel® Compute Module MFS5000SI User Guide...
  • Page 49: Figure 40. Removing Mezzanine Card

    5. Holding the mezzanine card by its edges, gently lift it from the socket and store it in an anti-static package. I/ O AF002406 Figure 40. Removing Mezzanine Card Intel® Compute Module MFS5000SI User Guide...
  • Page 50: Figure 41. Removing Standoffs

    8. Reinstall the top cover. For instructions, see “Replacing and Closing the Top Cover” on page 9. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page Intel® Compute Module MFS5000SI User Guide...
  • Page 51: Replacing The Cmos Battery

    2. If the compute module is installed in a server system, see “Removing a Compute Module from the Server System” on page 7 for removal instructions. 3. Remove the top cover. For instructions, see “Opening and Removing the Top Cover” on page Intel® Compute Module MFS5000SI User Guide...
  • Page 52: Figure 42. Cmos Battery Location

    10. Reinstall the server compute blade in the server system. For instructions, see “Installing a Compute Module into the Server System” on page 8 11. Run Setup to restore the configuration settings to the RTC. Intel® Compute Module MFS5000SI User Guide...
  • Page 53: Troubleshooting

    Is the operating system properly loaded? Refer to the operating system documentation. • Are all device drivers properly installed? • Are all installed components and the installed operating system listed in the Intel® Compute Module MFS5000SI Tested Hardware and Operating System List? Intel® Compute Module MFS5000SI User Guide...
  • Page 54: Hardware Diagnostic Testing

    Characters on the screen appear distorted or incorrect • No available storage • Network problems Try the solutions in the order given. If you cannot correct the problem, contact your service representative or authorized dealer for additional help. Intel® Compute Module MFS5000SI User Guide...
  • Page 55: Power Led Does Not Light

    Characters are Distorted or Incorrect Check the following: • Is the video monitor properly adjusted? See the manufacturer’s documentation for operating instructions. • Are the video signal cable and power cable connected properly? Intel® Compute Module MFS5000SI User Guide...
  • Page 56: No Available Storage

    No Available Storage Check the following: • Verify in the Intel® Modular Server Control GUI that virtual drive(s) are assigned to the compute module. • Ensure drive(s) assigned to the compute module are installed and operating properly.
  • Page 57: Problems With Newly Installed Application Software

    Devices are Not Recognized within the Operating System Operating systems include a limited set of device drivers by default. Ensure that you install all necessary drivers at the time you install the operating system. Intel® Compute Module MFS5000SI User Guide...
  • Page 58: Diagnostic Led Information

    Diagnostic LED Information The Intel® Compute Module MFS5000SI includes a number of diagnostic LEDs on the front of the compute module that can aid in troubleshooting your system. The following table lists these LEDs along with a usage description of each LED.
  • Page 59 The following table contains a partial list of the POST error beep codes enabled for the Intel® Compute Module MFS5000SI. The beep code sounds only when a critical error occurs or when the BIOS fails to boot to the operating system. Please note that not all error conditions are supported by BIOS beep codes.
  • Page 60 Intel® Compute Module MFS5000SI User Guide...
  • Page 61: A Getting Help

    Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). For an updated support contact list, see http://www.intel.com/support/9089.htm/...
  • Page 62: In Asia-Pacific Region

    Chile Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 Intel® Compute Module MFS5000SI User Guide...
  • Page 63 Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Compute Module MFS5000SI User Guide...
  • Page 64 Intel® Compute Module MFS5000SI User Guide...
  • Page 65: B Warranty

    “as is” unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
  • Page 66: Warranty Limitations And Exclusions

    Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
  • Page 67: Telephone Support

    Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
  • Page 68 Intel® Compute Module MFS5000SI User Guide...
  • Page 69: C Product Regulatory Requirements

    Product Ecology Requirements Intel has a system in place to restrict the use of banned substances in accordance with worldwide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all supplier, and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance.
  • Page 70: Component Regulatory Requirements Needed To Support System Level Certifications

    Item Requirement Description Y/N/D Product Ecology All materials, parts and subassemblies must not contain restricted materials as defined in Intel’s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers – http:// supplier.intel.com/ehs/environmental.htm Product Ecology Europe - European Directive 2002/95/EC -...
  • Page 71: Product Regulatory Compliance And Safety Markings

    Product Regulatory Compliance and Safety Markings No markings required on the board itself as it is evaluated as part of the end system. Intel® Compute Module MFS5000SI User Guide...
  • Page 72 Intel® Compute Module MFS5000SI User Guide...
  • Page 73: D Safety Information

    Indicates shock hazards that result in serious injury or death if safety instructions are not followed. Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intel® Compute Module MFS5000SI User Guide...
  • Page 74: Intended Application Uses

    AC power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Compute Module MFS5000SI User Guide...
  • Page 75: System Access Warnings

    Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Compute Module MFS5000SI User Guide...
  • Page 76: Rack Mount Warnings

    Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a Intel® Compute Module MFS5000SI User Guide...
  • Page 77: Other Hazards

    Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Compute Module MFS5000SI User Guide...
  • Page 78: Deutsch

    Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
  • Page 79: Zielbenutzer Der Anwendung

    • Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Compute Module MFS5000SI User Guide...
  • Page 80 Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 81: Warnhinweise Für Den Systemzugang

    Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Compute Module MFS5000SI User Guide...
  • Page 82: Elektrostatische Entladungen (Esd)

    Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Compute Module MFS5000SI User Guide...
  • Page 83: Andere Gefahren

    Vorsicht: Beachten Sie zur Vermeidung von Strahlung und Verletzungen die folgenden Hinweise: • Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Compute Module MFS5000SI User Guide...
  • Page 84: Français

    Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
  • Page 85: Domaines D'utilisation Prévus

    • Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Compute Module MFS5000SI User Guide...
  • Page 86 Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 87 Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Compute Module MFS5000SI User Guide...
  • Page 88: Décharges Électrostatiques (Esd)

    à la terre, exempte de charge statique, composants orientés vers le haut. Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Compute Module MFS5000SI User Guide...
  • Page 89: Autres Risques

    Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Compute Module MFS5000SI User Guide...
  • Page 90: Español

    Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
  • Page 91: Aplicaciones Y Usos Previstos

    Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Compute Module MFS5000SI User Guide...
  • Page 92 CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 93: Advertencias El Acceso Al Sistema

    Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Compute Module MFS5000SI User Guide...
  • Page 94: Descarga Electrostática (Esd)

    Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Compute Module MFS5000SI User Guide...
  • Page 95 Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Compute Module MFS5000SI User Guide...
  • Page 96 表示如果无视此 “ ? ? ? 项 ” ? ? ? ? ? ? ? 轻微人身伤害或财产损失的危险。 警告 表示如果无视此 “ ? ? ” ? ? ? ? ? ? ? 严重人身伤害的危险。 表示如果无视所示信息,即存在潜在的危险。 表示如果不遵守安全指导,存在可导致严重伤害或死亡的电击危险。 表示灼热组件或表面。 表示请勿触摸风机叶片,否则可能致伤。 表示拔下所有交流电线,断开交流电源 Intel® Compute Module MFS5000SI User Guide...
  • Page 97 通风良好,远离热源(包括直接日晒和散热器)。 • 远离振动源或物理震动。 • 与电气设备产生的强大电磁场隔离。 • 在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信 线路与调制解调器之间的连接。 • 提供正确接地的墙壁插座。 • 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: • 移举设备时遵守当地的职业健康与安全要求。 • 借助机械手段或其他合适的手段移举设备。 • 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接 通电源,就存在 5V 待机电源。要从系统切断电源,须从墙壁电源插座中拔下交流电线。您的系统可能 不止使用一根交流电线。请确保所有的交流电线都已拔下。打开机箱或增加或去除 任何热插拔组件之前,确保交流电线已拔下。 若非所需的确切类型,请勿尝试修改或使用交流电线。系统的每个电源供应设备都 需要一根单独的交流电线。 本产品的电源供应设备包含非用户维修部件。请勿打开电源供应设备。电源供应设 备包含非常危险的电压级、电流级和能量级。请与生产商联系维修事宜。 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,再将其 从服务器上移除。 Intel® Compute Module MFS5000SI User Guide...
  • Page 98 ⎯ 电源线的电气额定值须大于产品上标注的电流额定值。 ⎯ 电源线须拥有适合插座的安全接地插头或触点。 • 电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。 • 电源线须插入所提供的拥有合适接地的插座。 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: • 关闭所有与本产品相连的外设。 • 按下电源按钮至关闭状态,关闭系统。 • 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 • 断开与系统相连的所有线缆和通信线路。 • 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请 用螺钉或紧固件重新固定舱口盖。 • 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系 维修事宜. • 增加或替换任何非热插拔组件之前,请关闭服务器电源并断开所有电源线 。 • 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线 ,然后再从服务器上移除电源供应设备。 注意事项 如果服务器一直在运行,任何已安装的处理器和吸热设备都可能很热。除非要增加 或移除热插拔组件,否则请待系统冷却后再开盖。为避免在热插拔组件安装过程中 接触灼热组件,移除或安装热插拔组件时务须小心。 Intel® Compute Module MFS5000SI User Guide...
  • Page 99 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸 下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机 架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且 须标明为控制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地 。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地 或任何未喷漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将 主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要 使用主板包装。请勿将主板在任何表面上滑动。 Intel® Compute Module MFS5000SI User Guide...
  • Page 100 其他危险 替换电池 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的 电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 冷却和气流 注意事项 按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。 为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行 系统可能导致系统部件受损。安装机箱盖的步骤如下: 首先检查并确保系统内没有遗留的未固定工具或部件。 • 检查线缆、内插板和其他组件已正确安装。 • 按产品说明安装机箱盖。 • 激光外设或激光设备 注意事项 为避免幅射暴露和 / 或人身伤害: 请勿打开任何激光外设或激光设备的外壳 • 激光外设或激光设备为非用户维修设备 • 请与生产商联系维修事宜 Intel® Compute Module MFS5000SI User Guide...
  • Page 101: E Installation/Assembly Safety Instructions

    To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). Intel® Compute Module MFS5000SI User Guide...
  • Page 102 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Intel® Compute Module MFS5000SI User Guide...
  • Page 103: Deutsch

    Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Compute Module MFS5000SI User Guide...
  • Page 104 Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. Intel® Compute Module MFS5000SI User Guide...
  • Page 105 Telekommunikationsleitungen mit dem Modem bestehen; • "mit einer geerdeten Wechselstromsteckdose ausgerüstet sein; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Compute Module MFS5000SI User Guide...
  • Page 106: Français

    Procédez comme suit: 1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Compute Module MFS5000SI User Guide...
  • Page 107 • "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Compute Module MFS5000SI User Guide...
  • Page 108: Español

    Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Compute Module MFS5000SI User Guide...
  • Page 109 • "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Compute Module MFS5000SI User Guide...
  • Page 110: Italiano

    1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Compute Module MFS5000SI User Guide...
  • Page 111 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Compute Module MFS5000SI User Guide...
  • Page 112 Intel® Compute Module MFS5000SI User Guide...

Table of Contents