Table 64. CmmTable/cmmEntry (1.3.6.1.4.1.343.2.14.2.10.3.51.1) (Sheet 1 of 2)
OID
1
cmmTarget
2
cmmCurrent
3
cmmThresholdsAll
4
cmmUpperCritical
5
cmmUpperNonCritical
6
cmmLowerNonCritical
7
cmmLowerCritical
8
cmmUpperNonRecoverable
9
cmmLowerNonRecoverable
cmmMaximumExternalAvaila
10
bleCurrent
cmmMaximumInternalAvailabl
11
eCurrent
cmmMinimumExpectedOpera
12
tingVoltage
13
cmmSensorHealth
14
cmmSensorHealthEvents
15
cmmMinorAction
16
cmmMajorAction
17
cmmCriticalAction
18
cmmNormalAction
35
cmmfruBoardDescription
36
cmmfruBoardManufacturer
37
cmmfruBoardPartNumber
38
cmmfruBoardSerialNumber
cmmfruBoardManufactureDat
39
e
40
cmmfruProductDescription
41
cmmfruProductManufacturer
42
cmmfruProductPartNumber
MPCMM0001 Chassis Management Module Software Technical Product Specification
Download from Www.Somanuals.com. All Manuals Search And Download.
Object
Syntax
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
INTEGER
DisplayString
OCTET
STRING
OCTET
STRING
OCTET
STRING
OCTET
STRING
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
Access
Value
none
index
read-only
The current value of a sensor.
read-only
All thresholds of a sensor.
read-only
Upper critical thresholds
read-only
upper non-critical thresholds
read-only
lower non-critical thresholds
read-only
lower critical thresholds
read-only
upper non recoverable thresholds
read-only
lower non recoverable thresholds
read-write
Each unit is 100mA
read-only
Each unit is 100mA
read-write
Each unit is 0.5 Volt
Health information about a particular
location/sensor. This will be one of the
read-only
following: (0-OK, 1-Minor, 2-Major, 3-
Critical)
Events that contribute to the health of
read-only
the location/sensor. This is a list of
events happening on the location.
Used to configure user defined actions
read-write
when minor events occur.
Used to configure user defined actions
read-write
when major events occur.
Used to configure user defined actions
read-write
when critical events occur.
Used to configure user defined actions
read-write
when normal events occur.
Used to read the Board Description
read-only
from the FRU.
Used to read the Board Manufacturer
read-only
from the FRU.
Used to read the Board Part Number
read-only
from the FRU.
Used to read the Board Serial Number
read-only
from the FRU.
Used to read the Board Manufacture
read-only
Date from the FRU.
Used to read the Product Description
read-only
from the FRU.
Used to read the Product Manufacturer
read-only
from the FRU.
Used to read the Product Part Number
read-only
from the FRU.
SNMP
149
Need help?
Do you have a question about the NetStructure MPCMM0001 and is the answer not in the manual?