Intel NetStructure MPCMM0001 Software Instructions page 156

Chassis management module
Table of Contents

Advertisement

SNMP
Table 72. [FanTray/pem]Table/[fanTray/pem]Entry (1.3.6.1.4.1.343.2.14.2.10.[5/6].51.1)
OID
19
fanTrayMaximumSetting
20
fanTrayRecommendedSetting
21
fanTrayCurrentFanLevel
Table 73. [FanTray/pem]TargetTable/[fanTray/pem]TargetEntry (1.3.6.1.4.1.343.2.14.2.10.[5/
6].52.1) (Sheet 1 of 2)
OID
1
[fanTray/pem]Number
2
[fanTray/pem]Target
3
[fanTray/pem]Current
4
[fanTray/pem]ThresholdsAll
5
[fanTray/pem]UpperCritical
6
[fanTray/pem]UpperNonCritical
7
[fanTray/pem]LowerNonCritical
8
[fanTray/pem]LowerCritical
[fanTray/
9
pem]UpperNonRecoverable
[fanTray/
10
pem]LowerNonRecoverable
14
[fanTray/pem]SensorHealth
[fanTray/
15
pem]SensorHealthEvents
16
[fanTray/pem]MinorAction
17
[fanTray/pem]MajorAction
18
[fanTray/pem]CriticalAction
19
[fanTray/pem]NormalAction
[fanTray/
20
pem]fruBoardDescription
[fanTray/
21
pem]fruBoardManufacturer
[fanTray/
22
pem]fruBoardPartNumber
[fanTray/
23
pem]fruBoardSerialNumber
[fanTray/
24
pem]fruBoardManufactureDate
156
MPCMM0001 Chassis Management Module Software Technical Product Specification
Download from Www.Somanuals.com. All Manuals Search And Download.
Object
Syntax
DisplayString
DisplayString
DisplayString
Object
Syntax
INTEGER
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
INTEGER
DisplayString
OCTET
STRING
OCTET
STRING
OCTET
STRING
OCTET
STRING
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
Access
Value
read-only
The fantray's maximum setting.
read-only
The fantray's recommended setting.
read-only
The fantray's current fan level.
Access
Value
none
Index 1
none
Index 2
read-only
The current value of a sensor.
read-only
All thresholds of a sensor.
read-only
Upper critical thresholds
read-only
Upper non-critical thresholds
read-only
Lower non-critical thresholds
read-only
Lower critical thresholds
read-only
Upper non recoverable thresholds
read-only
Lower non recoverable thresholds
Health information about a particular
location/sensor. This will be one of
read-only
the following: (0-OK, 1-Minor, 2-
Major, 3-Critical).
Events that contribute to the health
read-only
of the location/sensor. This is a list of
events happening on the location.
Used to configure user defined
read-write
actions when minor events occur.
Used to configure user defined
read-write
actions when major events occur.
Used to configure user defined
read-write
actions when critical events occur.
Used to configure user defined
read-write
actions when normal events occur.
Used to read the Board Description
read-only
from the FRU.
Used to read the Board
read-only
Manufacturer from the FRU.
Used to read the Board Part Number
read-only
from the FRU.
Used to read the Board Serial
read-only
Number from the FRU.
Used to read the Board Manufacture
read-only
Date from the FRU.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NetStructure MPCMM0001 and is the answer not in the manual?

Questions and answers

Table of Contents