CAUTION! If the bottom gates are in position 4 or 5, they must be completely
opened once or twice using the bottom gate lever. You must then
place them in position 1 or 2, close the drainage gates, and finally
move the bottom gate lever into the desired position.
Following calibration test sampling, close
the drainage gates by pulling the drainage
gate lever upwards and insert the calibra-
tion trays (1) with the opening facing down-
1
wards.
Important!
4
Since calibration test sam-
pling is carried out whilst sta-
tionary, it is not possible to
take field conditions and im-
pulse wheel (4) slip into ac-
count. For this reason, it is
recommended that you carry
out automatic calibration of
the impulse wheel range/path
per impulse on the field (see
the operating instructions for
the electronic seed drill con-
trol system).