9.3 Internal Battery Operation

9.3.1 General

The internal battery consists of a rechargeable battery system with
automatic recharge, self-test, and power switching capability. The
internal battery capacity will provide approximately 1 hour of operation at
standard temperatures and 30 minutes (minimum) of operational
capacity over the operational temperature range.
When power is lost to the AV-30-E, the following will occur:
1. While AV-30-E is aligning, the unit will continue in battery mode if
power is lost. Once aligned it will shut down.
2. If any button is pressed after power is lost, the AV-30-E will stay
in battery mode.
3. If the AV-30-E senses airspeed or GPS groundspeed, it will stay
in battery mode. Pitot and static ports must be properly
connected.
If the AV-30-E needs to be shut down after removing power, push and
hold the left and right buttons until the unit shuts down.
See the Pilots Guide UAV-1004233-001 §10 Internal Battery Operation
for additional operational information.