    1 Revision History Revision Date Comments 7/21/2021 Initial release Service Bulletin UAV-1005757-001 Rev A...
  • Page 4: Warnings / Disclaimers

    2 Warnings / Disclaimers uAvionix is not liable for damages arising from the use or misuse of this product. This equipment is classified by the United States Department of Commerce's Bureau of Industry and Security (BIS) as Export Control Classification Number (ECCN) 7A994.
  • Page 5: Table Of Contents

    3 Table of Contents Revision History ................... 3 Warnings / Disclaimers ................ 4 Table of Contents ................5 Planning Information ................7 Applicability ................... 7 Description ..................8 Time Required ................8 Weight and Balance ..............8 Electrical Load Data ..............8 Applicable Publications ..............
  • Page 6 System Checkout ................25 Support ....................25 Maintenance Record ................26 Service Bulletin UAV-1005757-001 Rev A...
  • Page 7: Planning Information

    This Service Bulletin applies to uAvionix AV-30-E UAV-1004035-001 and UAV-1004035-002 with operating software release 2.1.0 or earlier. For magnetometer enhancement, the unit must be sent in to uAvionix for hardware update. For improvement in DG function, the unit must be connected to pitot and static.
  • Page 8: Description

    Pitot and static shall be connected to the DG if not already installed. 4.3 Time Required For Internal Magnetometer addition, unit must be returned to uAvionix to update hardware. For software only update in the field, up to 90 minutes is required to perform this update procedure.
  • Page 9: Required Items

    Support website at no charge, at: https://uavionix.com/av-30-e-service-bulletin-software-upgrade-2-1-1/ Click on the link in the section AV-30-E v2.1.1 Firmware and save it to your PC or mobile device. Ensure the software and any necessary update tools have been downloaded prior to visiting the aircraft.
  • Page 10: Av-Link

    The uAvionix AV Update Tool is available on the website linked above in the section AV Update Tool. Download it to your PC. 5.2 AV-Link The following items are required to perform the update when using AV-Link over Wi-Fi: Quantity Description...
  • Page 11: Pc Serial Update

    Note: AV-Link must not be installed if performing an update using the PC serial update procedure. 7.2 Serial Update Procedure 1. Connect the AV-30-E to the Windows PC through the DB-9 connection previously installed in Section 7.1. Service Bulletin UAV-1005757-001 Rev A...
  • Page 12 AV Updater Tool. 6. Once proper connection has been made, select the firmware file to upload to the AV-30-E by clicking “Open File” and selecting the previously downloaded firmware file as identified in Table 5-1 Software Update Files.
  • Page 13 displayed SHA1 hash to that in Table 5-1 Software Update Files. Note that the hash is not case sensitive. 7. When confirmed, press OK and the main dialog will re-appear. 8. Select “Write Firmware” to begin the upload. DO NOT POWER OFF THE AV-30 OR CLOSE THE UPDATER TOOL UNTIL THE UPDATE IS COMPLETE.
  • Page 14 When the AV Update Tool displays “100%” and the lower status reads “Update Complete” the process is complete. 10. The unit will automatically restart. Upon restart of the unit, verify the startup screen indicates the updated software version. 11. If the unit was removed to perform the update it can now be reinstalled as per the installation manual.
  • Page 15: Av-Link Update

    8.1 AV-Link Update Preparation If AV-Link is already installed in the aircraft, proceed to Section 8.2. If AV-Link is available but not installed, follow the installation procedure as described in “AV-30-E Installation Manual” UAV-1004234-001 Rev C, Section 11.1. 8.2 AV-Link Update Procedure After the AV-Link and AV-30 have been installed, AV-30 firmware updates can be performed using the AV-Link web interface.
  • Page 16 1. Hold down left and right button while applying power to the AV- 30 and AV-Link. Hold for 5 seconds. This will allow the AV- 30 to enter the bootloader mode. The screen will remain black. Do not interrupt power during the update process.
  • Page 17 3. In a Web Browser (such as Google Chrome) navigate to the AV-Link home page via the following URL: 192.168.4.1 A page similar to shown on the right should appear. 4. At the bottom of the page select AV Firmware Update Service Bulletin UAV-1005757-001 Rev A...
  • Page 18 5. On the AV Display Firmware Update page select Choose File then select the previously downloaded AV-30 firmware. 6. Once the file has been selected click Start Update DO NOT power off the unit or close the web browser until the update is complete.
  • Page 19: Post-Accomplishment Verification And Actions

    Post-Accomplishment Verification and Actions On restart, verify that the startup screen displays the correct version number. Access the Installation Menu to complete post-accomplishment verification steps. 1. To enable access to the Installation Menu, ensure the unit is completely turned off. Push and hold the main control knob in while power is applied.
  • Page 20: Serial 3

    Table 5-1 Software Update Files. Note that the checksum is not case sensitive. If all software fields match, continue with these instructions. Otherwise, contact uAvionix Support. The following sections detail new Installation Menu options and should be reviewed and set appropriately for your aircraft. Access the Installation Menu and rotate the center knob to select these settings.
  • Page 21: Vibe Monitor

    The factory setting for non-magnetometer equipped units is NONE, and the factory setting for magnetometer equipped units is MAG1. Leave the AID Mode set to the default, unless otherwise direct by uAvionix Support. To change, push the center knob and rotate to select your choice of magnetometer aiding and then push the center button to confirm your choice.
  • Page 22: Gyro Cal

    Record the data on the screen to share with uAvionix Support. Push the center button again to stop monitoring vibration and return to the Installation Menu. 9.4 GYRO CAL As units age or experience unusual conditions, the precision gyroscopic sensors may need to be re-calibrated. This can be accomplished in the field using the procedure noted here.
  • Page 23 1. Ensure the aircraft is completely motionless and on the ground during the next several steps. 2. In the Installation Menu, rotate the center knob until “GYRO CAL” is displayed. Push the center button to enter calibration mode. Confirm by pushing the right button. 3.
  • Page 24: Mag Cal

    This need will be indicated by a red flag indicating “NOMAG”, once the “ALIGN” flag extinguishes. For more information on Mag Calibration, reference the procedure as described in “AV-30-E Installation Manual” UAV-1004234-001 Rev C Section 13.2.3. The Mag Calibration feature can be accessed by selecting “MAG CAL”...
  • Page 25 The AV-30 will retain all calibration unless a hard reset is accomplished. 10 System Checkout Perform the System Checkout procedure as described in “AV-30-E Installation Manual” UAV-1004234-001 Section 13.2 prior to returning to service. 11 Support For additional questions or support please visit: http://www.uavionix.com/support/...
  • Page 26 When post-accomplishment verification and system checkout is completed, make appropriate entries in the Aircraft Maintenance Log Book. Maintenance Record Service Bulletin UAV-1005757-001 to install software v2.1.1 for AV-30-E UAV-1004035-( ), has been complied with. A copy of this form must be submitted by visiting: https://uavionix.com/logbook/...