Miscellaneous Non-Fault Messages - Genicom 4810 User Manual

Hide thumbs Also See for 4810:
Table of Contents

Advertisement

Operator Troubleshooting
(continued)
DISPLAY
:FntCksm X
:DLF Pstn
:DLF Cksum
:DLF Numbr
:DLF Dnsty
:DLF DotSp
:DLF Term
:DLF Memry
SGL FAILED ST
TABLE 3-1
(continued)
Soft Fault Displays
MEANING
The font pair specified by X has failed the
checksum test (See Note 2).
The download font contains
an
invalid
character position.
The download font has a load checksum error.
The download font has
an
invalid font number.
The download font contains
an
invalid font
density/width.
The download font contains
an
adjacent dot
error.
The download font has
an
invalid terminator.
There is insufficient memory for the download
font.
The SmartGraphics controller failed self-test.
Note
1:
When a defective wire driver or actuator is found,
n
will
indicate the position
(1 -
66
for 800-lpm or
1 - 33
for 400-
lpm).
Note
2: X -
font
EPROM
set
1-4
or download
RAM 5.
If all installed
fonts fail the checksum test, the
Fault:No Font
message will
be displayed.
Miscellaneous Non-Fault Messages
3-4
The following displays indicate printer status:
When the display is preceded by a :, either
Online
or
Local
will be
displayed in front of the following fault messages:
DISPLAY
MEANING
:Ready
The serial interface CB lead is true.
VFU
A
valid
VFU
has been downloaded.
Local:Remote
Printer deselected by host via received
DC3.
Tearoff
Paper is
in
position for tear
off at
rear exit.
TopTearoff
Paper is in position for tear off at top exit.
No\' 93

Advertisement

Table of Contents
loading

This manual is also suitable for:

4840

Table of Contents