VACON® 1000 Fieldbus Options
Operating Guide
6.3 Hardware Description
1
2
7
6
Illustration 25: Components of the DeviceNet™ Option
1
RS485 terminal
2
RS232 terminal
3
Indicator lights
4
LED display
6.3.1 Indicator Light Definitions
Table 45: Indicator Light Definitions
Indicators
Status
MS
Off
Green on
Green blinking
Red blinking
Red on
Red+Green blinking
NS
Off
Green blinking
Green on
Red blinking
Red on
RX
Green blinking
66 | Danfoss A/S © 2023.09
3
4
5
Description
No power supply or indicators are not working normally.
Working normally.
Not correctly configured.
Modbus communication faults (such as no slave station can be scanned).
Error occurred. Contact support.
Self-testing is ongoing.
The repetitive MAC ID detection is not successful or no power supply.
The devices are online but there are no connections established.
The devices are online and there are connections established.
One or more I/O connections have timed out.
The device detects errors and cannot communicate, such as there is repetitive DeviceNet ad-
dress on the network.
Serial port is receiving data.
5
DIP Switch
6
DeviceNet terminal
7
DeviceNet address
AQ454734633756en-000101 / 172K1112
DeviceNet™