Send Line Loopback - Paradyne FrameSaver SLV 9124 User Manual

Hide thumbs Also See for FrameSaver SLV 9124:
Table of Contents

Advertisement

Send Line Loopback

9124-A2-GB20-00
The remote Line Loopback (LLB) up and down codes are in-band codes that
allow control of a remote device. The LLB Up code invokes a line loopback in the
remote unit while the LLB Down code terminates the remote line loopback.
Network loopbacks are defined in AT&T TR 62411.
Main Menu
Test
A remote LLB cannot be started when one of the following tests is active:
Any Loopback on the same interface.
Send FT1 Loopback or Data Channel Loopback on the synchronous
data port.
Data Channel Loopback on the frame relay link on this network interface.
Procedure
To start and stop a Remote Line Loopback:
1. Follow this menu selection sequence:
Main Menu
Test
2. Select the code Up or Down in the Send Line Loopback field.
— Up – Puts a remote device in loopback.
— Down – Takes the remote device out of loopback.
3. Highlight Send and press Enter to start the test. The code is sent for
10 seconds.
4. View the length of time that the test has been running in the Result column.
March 2000
Network Physical Tests
Network Physical Tests
Troubleshooting
Send Line Loopback
6-27

Advertisement

Table of Contents
loading