Alarms - Paradyne FrameSaver SLV 9124 User Manual

Hide thumbs Also See for FrameSaver SLV 9124:
Table of Contents

Advertisement

Alarms

9124-A2-GB20-00
The following table describes the alarm conditions that will generate an SNMP
trap for a physical interface, and the frame relay LMIs and DLCIs. These alarm
conditions also generate Health and Status messages seen on the System and
Test Status screen.
Main Menu
Status
Table 6-1. Alarm Conditions (1 of 6)
Alarm Condition
What It Indicates
AIS at Network 1
An Alarm Indication Signal
(AIS) is being received by
the interface. AIS is an
unframed, all ones signal.
AIS at DSX-1
For the DSX-1 interface,
the attached DTE is
transmitting an AIS.
EER at Network 1
The error rate of the
received network signal
exceeds the currently
configured threshold. This
condition only occurs if the
network interface is
configured for ESF framing.
This condition clears when
the error rate falls below the
threshold value, which may
take up to 15 minutes.
CTS down to
The CTS control lead on
Port-1 Device
the device's interface is off.
March 2000
System and Test Status
What To Do
For the network interface, report
the problem to your T1 service
provider.
For the DSX-1 interface, check
the DTE attached to the
interface.
Check DTR and RTS from
Port-1.
Troubleshooting
Verify that the network cable is
securely attached at the
network interface.
Contact your network provider.
Verify that the port is enabled.
Check DTR from the user data
port.
6-7

Advertisement

Table of Contents
loading

Table of Contents