Paradyne FrameSaver SLV 9124 User Manual page 123

Hide thumbs Also See for FrameSaver SLV 9124:
Table of Contents

Advertisement

9124-A2-GB20-00
Table 5-7. Health and Status Messages (2 of 4)
Message
EER at Network 1
Link Down Administratively,
2
frame relay link
LMI Discovery in Progress,
2
frame relay link
LMI Down, frame relay link
LOS at DSX-1
LOS at Network 1
Network Com Link Down
OOF at DSX-1
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.
March 2000
What It Indicates
The error rate of the received network signal
exceeds the currently configured threshold. This
condition only occurs if the network interface is
configured for ESF framing.
This condition clears when the error rate falls
below the threshold value, which may take up to
15 minutes.
The specified frame relay link has been disabled
by the unit due to LMI Behavior conditions or LMI
Protocol on another link is in a failed state.
This is not an alarm condition so System
Operational appears, as well.
Local Management Interface protocol discovery is
in progress to determine which protocol will be
used on the specified frame relay link.
2
The Local Management Interface(s) has been
declared down for the specified frame relay link.
A Loss of Signal (LOS) condition is detected on the
DSX-1 interface. Clears when the ratio of ones to
zeros received is greater than or equal to 12.5%.
Possible reasons include:
DSX-1 cable problem.
No signal being transmitted from the DTE.
A Loss of Signal (LOS) condition is detected on the
network interface. Clears when the ratio of ones to
zeros received is greater than or equal to 12.5%.
Possible reasons include:
Network cable problem.
No signal is being transmitted at the far-end
FrameSaver unit.
T1 facility problem.
The communication link for the COM port is down,
and the COM port is configured for Net Link.
An Out of Frame (OOF) condition is detected on
the DSX-1 interface. Possible reasons include:
Incompatible framing format between the DTE
and the FrameSaver unit.
DSX-1 cabling problem.
Operation and Maintenance
5-15

Advertisement

Table of Contents
loading