Paradyne FrameSaver SLV 9124 User Manual page 196

Hide thumbs Also See for FrameSaver SLV 9124:
Table of Contents

Advertisement

Setting Up NetScout Manager Plus for FrameSaver Devices
8-12
4. Click on the ... button to the right of indicated fields for a drop-down list from
which selections can be made. Minimally, configure the following fields:
Field
Domain
DLCI
Stats Type
Trap Variable
Key1
Key2
Type
Threshold
1
Latency MIB variables should be Absolute; all others should be Delta.
2
Generally, Rising is selected.
5. Select the OK button (at the bottom of the screen) to add this alarm.
6. Repeat Steps 3 through 5 until all traps are configured for all DLCIs.
Refer to Configuring Alarms in the NetScout Manager/Plus & NetScout Server
Administrator Guide for additional information.
March 2000
Select or Enter . . .
User Defined
DLCI number for trap being assigned
PARADYNE
Trap variable to be configured
The ifIndex for the frame relay logical interface is 1
DLCI number (same as DLCI above)
Absolute or Delta radio button
Rising, Falling, or Both radio button
Value that will trigger a trap.
1
2
9124-A2-GB20-00