Rmon Alarm And Event Defaults - Paradyne FrameSaver SLV 9124 User Manual

Hide thumbs Also See for FrameSaver SLV 9124:
Table of Contents

Advertisement

RMON Alarm and Event Defaults

The FrameSaver unit supports automatic generation of RMON alarm and event
information. Each alarm sets an SNMP variable to monitor. When the threshold
set for the monitored variable is exceeded, an SNMP trap or a log event is sent.
Event Defaults
Since all events sent are under the control of the FrameSaver unit, there is no
need to define multiple events for each alarm type, so only the following two
events need to be generated:
The alarm default tables starting on the next page show how each RMON default
alarm is set by the FrameSaver unit, shows the alarm and event types, the
interval used when generating alarms, and thresholds.
See
work, and
Rising Event Operation
If a rising threshold is crossed during the interval shown in a table (e.g., frames
dropped by the network), the event is armed and an alarm is generated at the
end of the interval. Only one alarm per event per interval is generated. The alarm
condition persists until the event has been disarmed (reset).
The event is disarmed when a falling threshold has been crossed and the rising
threshold has not been crossed during an interval, allowing the event to return to
its original disarmed state.
9124-A2-GB20-00
eventIndex
eventDescription
1
Default SLV Rising Event log-and-trap(4)
2
Default SLV Falling Event log-and-trap(4)
Physical Interface Alarm Defaults
Frame Relay Link Alarm Defaults
DLCI Alarm Defaults – Paradyne Area
DLCI Alarm Defaults – NetScout Area
Standards Compliance for SNMP Traps
Traps: RMON-Specific
March 2000
SNMP MIBs and Traps, and RMON Alarm Defaults
eventType
for information about how traps
for traps specific to remote monitoring.
eventCommunity
0
0
B-15

Advertisement

Table of Contents
loading

Table of Contents