D9412GV4/D7412GV4/D7212GV4
4

Passcodes, Access Credentials, and User Groups

4.1

Passcode or Token Worksheet

These programming items assign:
4.1.1

User Credentials

For the D9412GV4, there are 999 users (399 for D7412GV4 and 99 for D7212GV4) consisting
of no more than one passcode, one access credential and one key fob each.
4.1.2

Passcodes

In a control panel with factory default settings, only the master user has an assigned
passcode. A passcode can be three to six digits. Entering three digits in User ### chooses the
user. Programming the U001 Passcode assigns a passcode to the master user. User ID 0
(zero) is reserved for the service user and can not be assigned an access credential or a
keyfob.
Passcode Tamper
If a user enters six consecutive invalid passcodes at the same keypad, the control panel sends
a User Code Tamper report to the central station. The invalid passcode count resets when a
valid passcode is entered at the same keypad. Refer to R# Usr Code Tamper in Table 3.7,
Page 34 for information on enabling this report.
The passcode tamper condition is also reported in a manually initiated Extended Test Report
and to RPS through control panel diagnostics. As a result, the tamper condition is reset after
the successful completion of a manual report or when disconnecting from an RPS session.
The tamper condition is not reset when the control panel reboots.
4.1.3

User Group Window

Use U### User Group to enable and disable the U### Passcode for up to eight different time
periods throughout the day. Assign the number (1 to 8) programmed in U### User Group to a
User Windows #. If the user is outside a window, COMMAND DISABLED appears on the
keypad after the user enters the passcode and presses [ENTER].
NOTICE!
When using the Add/Change User function at the keypad, the authority levels and the changes
made affect the master user's passcode and the entire group's token or cards (D9412GV4 and
D7412GV4).
When using the ACCESS CONTROL LEVEL function at the keypad, the whole group is affected
by whether or not the level is on or off for access control functions only.
When using the DELETE USER? function, the whole group is deleted. You cannot delete each
user within the group individually. Use the ADD/CHG USER? function to change a user token
or card instead of deleting the whole group.
4.1.4

User Name

Each user group can be assigned one U### Name. This name is logged and sent to the central
station for all the users in the group. The user ID is used to differentiate which user's token or
card was executed.
Bosch Security Systems, Inc.
a passcode for users 001 to 999,
areas by authority level, and
a User Group Window.