D9412GV4/D7412GV4/D7212GV4
and any point being bypassed during the arming sequence report as POINT BYPASS along
with the Closing Report.
NOTICE!
When P## Defer Bypass Report is set to Yes and Closing Reports are suppressed by using
Closing Windows, the deferred Bypass Reports are not sent.
Bypass Reports for 24-hour points do not report If P## Report Bypass at Occurrence and P##
Defer Bypass Report are both set to No.
NOTICE!
To report the bypass at occurrence and when the area is armed, program P## Report Bypass
at Occurrence and P## Defer Bypass Report as Yes. A Command Bypass Report is sent as
soon as the user manually bypasses a point, and a supplemental Point Bypass Report is sent
with the Closing Report.
P## Cross Point
Default:
Selection:
Yes
No
NOTICE!
Do not use Cross points for Fire points.
The P## Cross Point option is designed to reduce false alarms. To achieve this, program two
or more points within a Cross Point Group with this prompt enabled. The Cross point feature
is available only on points where P## Pt Response is set to a value that generates an instant
alarm response.
The Cross Point feature does not activate when a fault occurs on Controlled points (Point
Types 1, 2 and 3) in the disarmed, entry delay, or exit delay states. Refer to Section P## Cross
Point, page 143 for additional programming requirements to program the Cross Point Timer.
If an abort window delay is needed for the cross zone alarms, all cross zone points in the
group must have P## Alarm Abort (refer to Section P## Alarm Abort, page 145) set to Yes.
NOTICE!
The Cross Point function applies only to Instant Alarm conditions. It does not apply to Trouble
or Supervisory conditions.
Cross zones have the ability to individually protect the intended area (e.g. motion detectors,
which overlap).
For SIA CP-01 Compliance:
P## Cross Point can be set to Yes or No.
P## Fire Point
Default:
Selection:
Yes
No
Bosch Security Systems, Inc.
Refer to the program record sheet
Yes or No
This point is a Cross Point.
This point is not a Cross Point.
Refer to the program record sheet
Yes or No
This point is a Fire point.
This point is not a Fire point.
Program Entry Guide
Points | en 143