Bosch D9412GV4 Program Entry Manual page 180

Table of Contents

Advertisement

180 en | SDI2 Modules
You can use one or both communication modules for central station reporting or RPS
communications. Optionally, you can use one of the B420 modules for communication with
automation software. While in this mode, you cannot use the module to communicate with
RPS nor with the central station.
RPS supports the configuration of the enclosure tamper on each of the Network Interface
Modules. Refer to Section Enclosure Tamper, page 179.
DHCP/AutoIP Enable
Default:
Selection:
DHCP is an auto configuration protocol that allows a computer to be automatically
configured, which eliminates the need for interaction by a network administrator. DHCP also
provides a central database that tracks computers that connect to the network, which
prevents two computers from accidentally being configured with the same IP address.
AutoIP enables dynamic IP addresses to be assigned to a device when the device is started
up. Whereas DHCP requires a DHCP server, AutoIP does not require a server when selecting
an IP address. A host configured with AutoIP receives an IP address of 169.254.xxx.xxx.
Keypad Programming of DHCP Enable
D1255
1.
2.
3.
4.
5.
6.
D1260
1.
2.
3.
4.
5.
6.
IPv4 Address
Default:
Selection:
A Domain Name Server (DNS) converts internet domain names or hostnames to their
corresponding IP addresses. When this is defined through the DHCP service, leave the default
value.
Keypad Programming of IPv4 Address
D1255
1.
2.
3.
F.01U.218.312 | 04 | 2012.03
Yes
Yes or No
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access the TOOLS MENU
and navigate to the PROGRAMMING option.
Press [ENT] to enter the PROGRAMMING option.
Press [ENT] at the MODULE PARAM option to enter it.
Press [ENT] at the DHCP ENABLE option. The keypad shows YES or NO.
To change the setting, press [EDIT] and then press the button for the desired option.
Press [Save] to save the changes.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access the Tools Menu and
navigate to the Programming option.
Press [ENTER] to enter the Programming option.
Press [ENTER] at the Module Parameters option to enter it.
Press [ENTER] at the DHCP Enable option. The keypad shows Yes or No.
To change the setting, press Edit softkey and then press the softkey for the desired
option.
Press the Save softkey to save the changes.
0.0.0.0
0.0.0.0 to 255.255.255.255
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access the TOOLS MENU
and navigate to the PROGRAMMING option.
Press [ENT] to enter the PROGRAMMING option.
Press [ENT] at the ADDRESS PARAM option to enter it.
Program Entry Guide