Bosch D9412GV4 Program Entry Manual page 135

Table of Contents

Advertisement

D9412GV4/D7412GV4/D7212GV4
control panel is in Exit Delay or is armed, entering a valid Passcode must be followed by the
[ENTER] or [ENT] key.
NOTICE!
If another Perimeter or Interior Follower Delay point trips while the area is already in entry
delay, the control panel adjusts the delay time to the Delay point with the least amount of
delay time.
When a user enters an area, a Perimeter point is faulted and the entry delay starts. If an
interior point must fault during entry delay to allow the user to disarm the area at a keypad,
program P## Type as 3 (Interior Follower).
For SIA CP-01 Compliance:
P## Entry Delay must be between 30 sec and 240 sec.
Tone Off
Default:
Selection:
Yes
No
This option enables and disables the entry delay warning tone for this point.
WARNING!
Do not set points to Yes if they are actually used to notify the user to disarm the system. The
possibility of false alarms increases if the entry delay warning is not used.
NOTICE!
Entry Tone can also be turned off when programming your CC Entry Tone in
Section 3.11 Keypad (Command Center), page 78, that allows you to manage the tone by
keypad.
NOTICE!
You might want to disable the entry tone in high security applications where you do not want
to annunciate entry delay.
P## Silent Bell
Default:
Selection:
Yes
No
Use this option to enter the amount of entry delay time that a user has after faulting a
Controlled point (P## Type 1, 2, 3) with a delayed response (D) (P## Pt Response) of 4, 5, 6,
7, or 8. DISARM NOW appears for the duration of the time programmed when the point is
faulted in the delay condition.
Bosch Security Systems, Inc.
Refer to the program record sheet
Yes or No
Disables the entry delay tone when this perimeter point is faulted.
This is intended for use with points set to P## Type 1 (Perimeter).
A tone sounds at keypads when this point starts entry delay.
Refer to the program record sheet
Yes or No
Activate the Silent Alarm Relay when this point enters into alarm.
Keypads do not sound the alarm tone for Non-fire points.
Activate either the Fire Bell relay or Alarm Bell relay and sound the
alarm tone at keypads when this point enters into alarm. If this is a Fire
point, it activates the Fire Bell relay programmed in Relay Parameters.
Otherwise, it activates the Alarm Bell relay. The amount of time and
pattern of the relay activation is programmed by area in Bell
Parameters.
Program Entry Guide
Points | en 135
F.01U.218.312 | 04 | 2012.03

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412gv4D7212gv4

Table of Contents