8.5.2
RF Diagnostics Keypad Menu (RFID Wireless Repeaters)
RF Points -- States
D1255
1.
2.
3.
4.
5.
D1260
1.
2.
3.
4.
5.
RF Points -- Signal Strengths
D1255
1.
2.
3.
Bosch Security Systems, Inc.
press [ENT] when the RF repeater you wish to remove shows. he keypad reads RF
REPEATER REMOVED.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access the Tools Menu and
navigate to the RF Repeaters option.
Press [ENT] to enter the Remove Repeaters option.
At the Repeater 1-8 option, enter the repeater number you wish to remove and press
[ENT] or scroll through the available devices to remove by pressing the Next softkey, and
then press [ENT] when the RF repeater you wish to remove shows. he keypad reads RF
Repeater Removed.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access the TOOLS MENU
and navigate to the RF DIAGNOSTICS option.
Press [ENT] to enter the RF DIAGNOSTICS option.
Press [ENT] at the RF POINTS option to enter it.
Press [ENT] to enter the STATES option.
Press [NEXT]. Within the STATES option, the menu will scroll through the following sub-
categories, with the results of the diagnostic check:
–
STATE
–
TAMPER
–
LOW-BATTERY
–
MAINTENANCE
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access the Tools Menu and
navigate to the RF Diagnostics option.
Press [ENTER] to enter the RF Diagnostics option.
Press [ENTER] at the RF Points option to enter it.
Press [ENTER] to enter the States option.
Press the Next softkey. Within the States option, the menu will scroll through the
following sub-categories, with the results of the diagnostic check:
–
State
–
Tamper
–
Low-Battery
–
Maintenance
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access the TOOLS MENU
and navigate to the RF DIAGNOSTICS option.
Press [ENT] to enter the RF DIAGNOSTICS option.
Press [ENT] to enter the SIGNAL STRENGTHS option.
Program Entry Guide
SDI2 Modules | en 193