138 en | Points
NOTICE!
Points bypassed (by the user, Sked, Swinger Bypass, or RPS) do not generate a Buzz On Fault
condition at the keypad.
NOTICE!
The buzz does not automatically stop when the point is restored when using Option 1 or 2.
The user must acknowledge the buzz before the buzz stops. However, when using Option 3,
the buzz stops automatically when the point restores to normal without user intervention.
P## Watch Point
Default:
Selection:
Yes
No
Use this option to allow a controlled point to generate a watch tone while the area is
disarmed and not faulted to a trouble or alarm condition.
P## Relay Response Type
Default:
Selection:
0
1
2
Use this option to cause a relay (1 to 127 for D9412GV4; 1 to 64 for D7412GV4) to respond
when a corresponding point with the same number (1 to 127) is faulted. This requires
connecting D8129 OctoRelays to Zonex Bus 1 and Zonex Bus 2 (D9412GV4 only). Refer to the
address settings on the back of the D9412GV4/D7412GV4/D7212GV4 Program Record Sheet
(P/N: F01U214958).
NOTICE!
Point 128 is reserved for use other than an actual point. Only the first 127 points can have an
associated relay. Relays are not available for Points 129 to 247.
NOTICE!
Do not use the Change Relays? function to toggle relays reserved for special functions.
Special function relays are Area and Panel Wide Relay functions as well as relays assigned to
CC## Enter Key Relay and P## Relay Response Type.
P## Display as Device
Default:
Selection:
Yes
No
F.01U.218.312 | 04 | 2012.03
Refer to the program record sheet
Yes or No
Activates Watch Mode responses if the point is faulted while the control
panel is in Watch Mode.
Does not activate Watch Mode responses for this point.
Refer to the program record sheet
0 to 2
Point state does not affect the operation of the corresponding relay.
Relay Follows Point: The relay corresponding with this point activates
when the point is faulted to any off-normal condition, even if the point
is bypassed. The relay automatically resets when the point returns to
normal.
Relay Latches: The relay corresponding with this point latches when
the point enters into an alarm condition. This relay provides a steady
output until the alarm is acknowledged by a valid passcode, then
cleared from alarm memory with an acknowledgment from the keypad.
Refer to the program record sheet
Yes or No
Display CHECK DEVICE when this point is off-normal.
Do not display CHECK DEVICE when this point is off-normal.
Program Entry Guide
D9412GV4/D7412GV4/D7212GV4
Bosch Security Systems, Inc.