Bosch D9412GV4 Program Entry Manual page 157

Table of Contents

Advertisement

D9412GV4/D7412GV4/D7212GV4
W# Open Window Stop
Default:
Selection:
Enter the time you want the control panel to end the Opening Window. The window stops at
the end of the minute.
Figure 6.1 Example Opening Window Timeline (Using Two Opening Windows on the Same Day)
Callout
1
2
3
4
5
6
7
8
9
NOTICE!
Make time entries using a 24-hour clock. For example:
Midnight is entered as 00:00
7:00 AM is entered as 07:00
2:45 PM is entered as 14:45
11:59 PM is entered as 23:59
This program item is one of three required to create an Opening Window. To program an
Opening Window, Open Early Begin and Open Window Start must also be programmed.
If the area is not disarmed by the time the Open Window Stop time expires, the control panel
generates a Fail to Open Report if A# Fail to Open is enabled in Area-Wide Parameters.
Opening Reports generated between the Open Window Start time and Open Window Stop
time can be suppressed by programming A# Disable O/C in Window as Yes. Refer to
Section W# Open Early Begin, page 155 for additional explanations of report features.
NOTICE!
Do not use a time of 23:59 as a window stop time unless another window begins on the next
day at 00:00.
Fail to Open Reports are not sent for windows that stop at 23:59.
Bosch Security Systems, Inc.
00:00
HH:MM (hours and minutes)
Description
Areas disarmed between midnight and 6 AM generate Opening Reports.
Areas disarmed between 6 AM and 7 AM generate Early to Open Reports.
If the area is disarmed between 7 AM and 8 AM regular Opening Reports are
generated. If Disable O/C in Window is programmed Yes the Opening Report is not
sent to the central station.
If the area is not disarmed by 8:01 AM, a Fail to Open Event is generated if Fail to
Open is programmed Yes in Opening and Closing Options.
If the user disarms the area between 8:01 AM and 12:59, PM a Late to Open Event
is generated.
Areas that are disarmed between 1 PM and 2 PM generate Early to Open Reports.
If the area is disarmed between 2 PM and 3 PM regular Opening Reports are
generated. If Disable O/C in Window is programmed Yes, the Opening Report is not
transmitted to the central station.
If the area is not disarmed by 3:01 PM, a Fail to Open Event is generated if Fail to
Open is programmed Yes in Opening and Closing Options.
If the user disarms the area between 3:01 PM and 11:59 PM, a Late to Open Event
is generated.
Program Entry Guide
Schedules (Skeds) | en 157
F.01U.218.312 | 04 | 2012.03

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412gv4D7212gv4

Table of Contents