134 en | Points
P## Point Response
Default:
Selection:
Key:
I = Instant alarm
D = Delayed alarm
S = Supervisory
Blank = Audible or visual response
Example of Controlled point:
Point Type = 1
Point Response = 8
Perimeter point with delayed alarm response when armed (opened or shorted) and no
response when disarmed.
Example of 24-hour point:
Point Type = 0
Point Response = 8
P## Entry Delay
Default:
Selection:
Use this option to enter the amount of entry delay time that a user has after faulting a
Controlled point (P## Type 1, 2, 3) with a delayed response (D) (P## Pt Response) of 4, 5, 6,
7, or 8. DISARM NOW appears for the duration of the time programmed when the point is
faulted in the delay condition.
NOTICE!
The D1255 alternates between DISARM NOW and the point text of the point that caused the
area to enter into entry delay.
If this time expires before disarming, or if the point is configured with an instant response (I),
an alarm occurs.
NOTICE!
Make entries in 5 sec increments. The programmer does not allow off-increment entries.
With Passcode Length set to a non-zero value, entering a valid Passcode during Entry Delay
disarms the system as soon as the last digit is entered. No other keys are required. When the
F.01U.218.312 | 04 | 2012.03
Refer to the program record sheet
0 - 9, A - F
Refer to the program record sheet
5 sec to 600 sec
Program Entry Guide
D9412GV4/D7412GV4/D7212GV4