D9412GV4/D7412GV4/D7212GV4
NOTICE!
Tokens and cards disarm according to this prompt. If this prompt is No, tokens disarm only
the Area to which the CC# is assigned. The user must have disarming rights for tokens and
cards programmed at the Disarm Level. The user does not need disarming and arming
authority for the keypad.
NOTICE!
You can use this prompt for a group of account-wide keypads that only arm the area to which
they are assigned, even if the user has a passcode with arming authority rights in all areas.
CC# Enter Key Relay
Default:
Selection:
0
1 to 128 (64, 24), A,
B, C
Program the relay number that activates momentarily for 10 sec when a user enters a valid
passcode and presses the [ENTER] key on the keypad. Two events are generated when this
function is used: RELAY ### SET with User ID, and RELAY ### RESET without User ID. The
system logs this action as two events.
NOTICE!
When CC## Passcode Function is set to Cycle Relay, the keypad cannot be used to passcode
arm or disarm.
Relays used for this function must not be shared with any other point, sensor reset, control
panel, or bell functions. Sharing can cause errors in relay operation.
CC# Pass Code Enter Function
Default:
Selection:
Arm/Disarm
Cycle Door
Bosch Security Systems, Inc.
0
0 to 128, A, B, C for D9412GV4
0 to 64, A, B, C for D7412GV4
0 to 24, A, B, C for D7212GV4
The [ENTER] key is not used to activate a relay.
Assign the relay number that activates when [ENTER] is pressed at this
keypad after the user enters a valid passcode.
With CC## Passcode Function is set to Cycle Relay, entering a valid code and pressing
[ENTER] at a keypad silences a ringing bell.
Using the relay programmed in CC# Enter Key Relay for a low-level access control strike
on a door does not shunt a point.
Arm/Disarm
Arm/Disarm, Cycle Door (D9412GV4/D7412GV4), Cycle Relay, Auto Re-
arm
Pass Code followed by ENTER (or ENT) key will start Master Delay Arm
for all areas within the users authorized scope if the current area is
disarmed. If the area is not disarmed, then all authorized areas will be
disarmed.
Pass Code followed by [ENTER] (or [ENT]) key will cycle the door
programmed in CC# Assign Door, then will actuate the users authorized
post access operations (Disarm, Perimeter Instant arm, or execute a
Custom Function) if enabled.
Program Entry Guide
Panel and Area Wide Parameters | en
F.01U.218.312 | 04 | 2012.03
83