Rigol DHO924S User Manual page 242

Digital oscilloscope
Hide thumbs Also See for DHO924S:
Table of Contents

Advertisement

DHO900 User Guide
1.888.610.7664
226
Click or tap the Type drop-down button to select "Edge" or "Pulse". Click or tap
the Source drop-down button to select the source.
- Edge Searches: After setting the search type to "Edge", you can select the slope
type. For details, please refer to
Threshold input filed to set the threshold with the pop-up numeric keypad or
use the corresponding multipurpose knob to set the value.
- Pulse Width Searches: After setting the search type to "Pulse", you can set the
trigger condition. For details, please refer to
or tap the Threshold input filed to set the threshold with the pop-up numeric
keypad or use the corresponding multipurpose knob to set the value.
3. Copy search setups
- Copy to Trigger
Click or tap To Trigger to copy the setup for the selected search type to the
same trigger type. For example, if the current search type is "Edge", clicking or
tapping To Trigger copies the search settings to the "
- Copy from Trigger
Click or tap From Trigger to copy the trigger setup for the selected search type
to the search setup. For example, if the current trigger type is "
clicking or tapping From Trigger copies the trigger settings to the "Edge"
search setup.
NOTE
To use the "To Trigger" or "From Trigger" function, the current trigger type should
correspond to the search type. Otherwise, a prompt message "Type mismatch" will pop up.
4. Marktable On/Off
Click or tap the MarkTable on/off switch to turn on or off the marktable display, as
shown in the figure below. The table lists all events of the current waveform in the
Waveform View. Zooming or adjusting the waveform causes the events in the table
to change. You can perform the following operations on the table:
- When acquisitions are stopped (STOP mode), click or tap any row of the table to
select the specified event. The inverted triangle mark of the selected event turns
red like
.
- Click or tap
at the upper-right side of the table to open the search menu.
- Select the gray title bar of the table to drag the table and move the table
window.
- Click or tap
at the upper-right side of the table to close the search menu.
www.calcert.com
15
10
20
5
25
0
30
Edge Trigger
. You can click or tap the
Pulse Width Trigger
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
. You can click
Edge Trigger
" settings.
Edge Trigger
",
sales@calcert.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dho900 seriesDho924Dho914sDho914

Table of Contents