11. OPTIONS AND PERIPHERAL EQUIPMENT
(2) Selection example of crimp terminals
(a) 200 V class
(b) 400 V class
11.10 Molded-case circuit breakers, fuses, magnetic contactors
CAUTION
Symbol
(Note 2) Crimp
terminal
a
FVD5.5-4
b (Note 1) 8-4NS
c
FVD2-4
d
FVD2-M3
e
FVD1.25-M3
f
FVD14-6
g
FVD5.5-6
h
FVD22-6
i
FVD38-8
j
FVD5.5-8
k
FVD8-6
Note 1. Coat the crimping part with an insulation tube.
2. Some crimp terminals may not be mounted depending on the size. Make sure to use the
recommended ones or equivalent ones.
Symbol
Crimp terminal
(Note)
a
FVD5.5-4
b
FVD2-4
c
FVD2-M3
d
FVD5.5-6
e
FVD5.5-8
f
FVD2-6
g
FVD8-6
h
FVD8-8
i
FVD14-8
Note. Some crimp terminals may not be mounted depending on the size. Make sure to use the
recommended ones or equivalent ones.
To prevent the servo amplifier from smoke and a fire, select a molded-case circuit
breaker which shuts off with high speed.
Always use one molded-case circuit breaker and one magnetic contactor with one
servo amplifier.
POINT
For the selection when the servo amplifier is used with the DC power supply
input, refer to app. 1.4.
Servo amplifier-side crimp terminals
Applicable tool
Body
Head
YNT-1210S
YHT-8S
YNT-1614
YNT-2216
YF-1
YNE-38
YNT-1210S
YF-1
YNE-38
YF-1
YNE-38
YNT-1210S
YF-1/E-4
YNE-38
Servo amplifier-side crimp terminals
Applicable tool
Body
Head
YNT-1210S
YNT-1614
YNT-1210S
YNT-1210S
YNT-1614
YF-1
YNE-38
11 - 65
Manufacturer
Dice
DH-122
DH-112
JST
DH-123
DH-113
DH-124
DH-114
DH-121
DH-111
Manufacturer
Dice
JST
DH-121/DH-111
DH-122/DH-112

Advertisement