7. SPECIAL ADJUSTMENT FUNCTIONS
(4) Vibration suppression control manual mode
Measure work-side vibration and device shake with the machine analyzer or external measuring
instrument, and set the following parameters to adjust vibration suppression control manually.
POINT
When load-side vibration does not show up in servo motor-side vibration, the
setting of the servo motor-side vibration frequency does not produce an effect.
When the anti-resonance frequency and resonance frequency can be confirmed
using the machine analyzer or external equipment, do not set the same value
but set different values to improve the vibration suppression performance.
Setting item
Vibration suppression control - Vibration
frequency
Vibration suppression control - Resonance
frequency
Vibration suppression control - Vibration
frequency damping
Vibration suppression control - Resonance
frequency damping
Vibration suppression
control 1
[Pr. PB19]
[Pr. PB20]
[Pr. PB21]
[Pr. PB22]
7 - 11
Vibration suppression
control 2
[Pr. PB52]
[Pr. PB53]
[Pr. PB54]
[Pr. PB55]