5. PARAMETERS
No./
Setting
symbol/name
digit
PA25
Set a permissible value of overshoot amount for one-touch tuning as a percentage of
the in-position range.
OTHOV
Note that setting "0" will be 50%.
One-touch
tuning -
Overshoot
Setting range: 0 to 100
permissible
level
PA26
_ _ _ x Torque limit function selection at instantaneous power failure
*AOP5
0: Disabled
Function
1: Enabled
selection A-5
When an instantaneous power failure occurs during operation, you can save electric
energy charged in the capacitor in the servo amplifier by limiting torque at
acceleration. You can also delay the time until [AL. 10.2 Voltage drop in the main
circuit power] occurs with instantaneous power failure tough drive function. Doing
this will enable you to set a longer time in [Pr. PF25 SEMI-F47 function -
Instantaneous power failure detection time].
The torque limit function at instantaneous power failure is enabled when "SEMI-F47
function selection" in [Pr. PA20] is "Enabled (_ 1 _ _)".
_ _ x _ For manufacturer setting
_ x _ _
x _ _ _
Function
5 - 25
Initial
value
[unit]
0
[%]
0h
0h
0h
0h