5. PARAMETERS
5.2.2 Gain/filter setting parameters ([Pr. PB_ _ ])
No./
Setting
symbol/name
digit
PB01
_ _ _ x Filter tuning mode selection
FILT
Set the adaptive filter tuning.
Adaptive
Select the adjustment mode of the machine resonance suppression filter 1. Refer to
tuning mode
section 7.1.2 for details.
(adaptive
0: Disabled
filter II)
1: Automatic setting
2: Manual setting
_ _ x _ For manufacturer setting
_ x _ _
x _ _ _
PB02
_ _ _ x Vibration suppression control 1 tuning mode selection
VRFT
Select the tuning mode of the vibration suppression control 1. Refer to section 7.1.5
for details.
Vibration
suppression
0: Disabled
control tuning
1: Automatic setting
mode
2: Manual setting
(advanced
_ _ x _ Vibration suppression control 2 tuning mode selection
vibration
Select the tuning mode of the vibration suppression control 2. To enable the digit,
suppression
set "Vibration suppression mode selection" to "3 inertia mode (_ _ _ 1)" in [Pr.
control II)
PA24]. Refer to section 7.1.5 for details.
0: Disabled
1: Automatic setting
2: Manual setting
_ x _ _ For manufacturer setting
x _ _ _
Function
5 - 26
Initial
value
[unit]
0h
0h
0h
0h
0h
0h
0h
0h

Advertisement