10 Operation
Procedure:
1. Activate the Wi-Fi access point of the inverter. To do this, tap on the enclosure lid of the inverter twice.
☑ The blue LED flashes slowly for approx. 2 minutes. The Wi-Fi access point is then activated for approx. 30
minutes. Once this period has expired, the Wi-Fi access point is deactivated automatically.
2. Search for Wi-Fi networks with your smart device.
3. Select the SSID of the product SMA[serial number] in the list with the detected Wi-Fi networks.
4. Enable the WPS function on the inverter. To do this, tap on the cover of the inverter enclosure another two times
one after the other.
☑ The blue LED flashes for approx. 2 minutes. The WPS function is then activated for approx. 2 minutes. After
this time, the WPS function is deactivated automatically.
5. Open the web browser of your smart end device and enter http://smalogin.net in the address bar.
6. If the login page of the user interface does not open, enter the IP address 192.168.12.3 or, if your smart end
device supports mDNS services, SMA[serial number].local or http://SMA[serial number] in the address bar
of the web browser.

10.4.3.4 Wi-Fi Connection via Device-specific Wi-Fi Password (WPA2-PSK)

1. Activate the Wi-Fi access point of the inverter. To do this, tap on the enclosure lid of the inverter twice.
☑ The blue LED flashes slowly for approx. 2 minutes. The Wi-Fi access point is then activated for approx. 30
minutes. Once this period has expired, the Wi-Fi access point is deactivated automatically.
2. Search for Wi-Fi networks with your smart device.
3. Select the SSID of the product SMA[serial number] in the list with the detected Wi-Fi networks.
4. Enter the device-specific Wi-Fi password (see WPA2-PSK on the type label).
5. Open the web browser of your smart end device and enter http://smalogin.net in the address bar.
☑ The welcome or login page of the user interface is displayed.
6. If the login page of the user interface does not open, enter the IP address 192.168.12.3 or, if your smart end
device supports mDNS services, SMA[serial number].local or http://SMA[serial number] in the address bar
of the web browser.
10.5

Design of the User Interface

The user interface of all SMA products powered by ennexOS and the user interface of Sunny Portal powered by
ennexOS are uniform.