Technogym DGK02U0 Technical Service Manual page 75

Table of Contents

Advertisement

TECHNOGYM RUN Technical Service Guide
Rev. 1.0
ER-
ROR
ERROR DESCRIPTION
CODE
24
OVER-TEMPERATURE SENSOR: Mal-
function of the temperature sensors due
to a connection problem or a sensor fault.
[1] Red circle means damaged contact, green circle means regular contact.
[2] detailed view of the ferrite on the motor encoder.
[*] Click the button 'Yes' on the display to try to make the error disappear.
TSG-00284-EN- Uncontrolled copy if printed
- Check for dust in the drive components.
If necessary, clean the drive.
- If it is always present even when the
equipment has just been turned on, with
the electronics cold, replace the drive
(Low Kit).
Tab. 20
Fig. 29
SOLUTION
- 75 -