3.11 STOP AND EMERGENCY SIGNAL MANAGEMENT
TECHNOGYM RUN has three emergency levels:
1. STOP button on the DISPLAY
2. CENTRAL STOP button
3. EMERGENCY STOP
WARNING: If the emergency stop is activated while the equipment is being used at
any gradient, the rotating belt will turn freely, there is no braking. In this condition the
weight of the user and gravity can cause unintended acceleration. Hold onto the side
supports.
3.11.1
EMERGENCY STOP CONTROL
The emergency stop consists of a device that incorporates an NC contact (normally closed), which
switches from the open state when the user pulls the cord.
Fig. 13 - Emergency control scheme (working condition)