Hyundai 35DS-7 Operation Manual page 212

Table of Contents

Advertisement

2. STARTING CIRCUIT
1
1
)
OPERATING FLOW
Battery(+) terminal
T
T
he engine can be started only when the gearshift is in neutral position.
(1)
When start key switch is in ON position
Start switch ON [CS-2(4)]
(2)
When start key switch is START position
Start switch START[CS-2(2)]
I/conn[CN-1(12)]
2)
CHECK POINT
Engine
Running
GND : Ground
35D/40D/45D-7
(
)
Start motor[CN-45(B+)]
Fuse box[No.3
Fuse box[No. 11]
Start relay[CR-23]
Key switch
ON
Fusible link[CN-95]
Start relay[CR-23]
8]
Engine stop relay[CR-47(2)]
I/conn[CN-1(10)]
Neutral relay[CR-5(4)
Check point
- GND (Battery B+)
- GND (Fusible link)
- GND (Fuse box No.3, 11)
- GND (Start key)
- GND (Anti restart relay)
7-16
Start switch[CS-2(3)]
Alternator[CN-74(2)]
(2)]
Voltage
24V