23
Fuel Line
1. Pull out locking clip.
2. Push in on release tab.
3. While pushing in on release tab, pull fuel line off nipple.
3050
Figure 23-13 Fuel Line Connector – To Disconnect
FUEL LINE INSTALLATION
1.
At fuel tank:
1.1.
Clean the nipple on top of fuel pump module.
1.2.
Push fuel line fully onto nipple until it locks in place (Figure 23-14, Page 23-18).
1.3.
Engage locking clip by pushing in until fully seated and completely prevents the line from being pulled
off nipple.
2.
At engine:
2.1.
Connect fuel line to throttle body and secure with spring clamp. See following DANGER.
DANGER
• Ensure line is connected properly to avoid a leak that can cause a fire.
3.
Clean spilled and remove any drained gasoline from the area.
4.
Connect battery. See Side-Post Battery: Connecting the Battery-Gasoline Vehicles on page 1-5.
See Top-Post Battery: Connecting the Battery-Gasoline Vehicles on page 1-5.
5.
Place the Forward/Reverse handle in the NEUTRAL position, chock the wheels, and the neutral lockout switch in
the MAINTENANCE position (Figure 26-1, Page 26-1).
6.
Turn the key switch to the ON position and check for fuel leaks. Repeat as necessary to build fuel pressure.
Any leaks found must be fixed.
DANGER
• Repair all fuel leaks before returning the vehicle to service.
7.
If no leaks are found, place the neutral lockout switch in the OPERATE position (Figure 26-1, Page 26-1).
Page 23-18
2016 Carryall 500 and 700 Maintenance and Service Manual
3
2
1
FUEL SYSTEM: GASOLINE VEHICLES
1. Push fuel line onto nipple until it locks into place.
2. Push in locking clip until fully seated.
3051
Figure 23-14 Fuel Line Connector – To Connect